1.9: Technical Specifications1.9: Technical Specifications
Interface
RS232 & RS485 Asynchronous 8 data bits, no parity, 1 stop bit
Connectors
Slave Ports 1 & 2 Half-duplex RS485
Slave Ports 3–16 DB-9F DTE type RS232
Master/Modem Port DB-9F DTE/DCE selectable RS232
Phone Line RJ-11
Size 3.5” (8.8 cm)H x 19.0” (48.26 cm)W x 8.08” (20.52 cm)D
Weight 12 lbs (5.4kg)
LEDs Power, Modem-Connect, Data Activity of Slave Ports (RxD, TxD, RTS)
Data Rate 600–57.6k BPS; All standard rates, port specific
Signals Supported
Master Port/Modem Port TxD, RxD, CTS, RTS, DCD, DTR
Slave Ports (1–16) TxD, Rxd, CTS, RTS
Flow Control
Master Port/Modem Port RTS/CTS
Slave Ports (1–16) RTS/CTS or none (port specific)
Hang-up Time (disconnect) No Hang-up, 5 minutes, 10 minutes
Reset Time No Reset, 5 minutes, 10 minutes
Buffer Size Two 16k buffers
Isolation 1500V DC
Control Power Options
Suffix -115A 115V AC +/-20%
Suffix -D2 125V AC/DC +/-20%
Suffix -D 24–48V DC +/-20%
Suffix -230A 230V AC +/-20%
Control Power Burden 10VA Maximum
Operating Temperature -20 to +70°C
Humidity Up to 95% non-condensing