User Manual
Page  14  of  15 
APPENDIX
Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste 
must be handled separately as special treatment is necessary. 
Recycling facilities are now available for all customers at which you can deposit 
your  old  electrical  products. Customers  will  be  able  to  take  any  old  electrical 
equipment to participating civic amenity sites run by their local councils. Please 
remember that this equipment will be further handled during the recycling process, 
so please be considerate when depositing your equipment. Please contact the 
local council for details of your local household waste recycling centres. 
TECHNICAL DATA 
P16HP 
P18HP 
Capacity 
Cooling 
4.6 kWh 
16,000 BTU 
5.2 kWh 
18,000 BTU 
Heating 
4.2 kWh 
14,000 BTU 
4.7 kWh 
16,000 BTU 
Rated Input 
Cooling 
1769W 
2000W 
Heating 
1826W 
2043W 
Running Current 
Cooling 
8.0 Amps 
9.3 Amps 
Heating 
8.4 Amps 
9.4 Amps 
Noise (sound power) 
<65dB(A) 
<65dB(A) 
Permitted Excessive 
Operating Pressure 
1.0/2.6MPa 
1.0/2.6MPa 
Maximum Allowable 
Pressure 
1.2/3.2Mpa 
1.2/3.2Mpa 
Power Supply 
220-240V/50Hz 
220-240V/50Hz 
Net Weight 
29 kgs 
30 kgs 
Refrigerant Quantity 
225g 
300g 
Dimensions 
(L*D*H) 
470*370*764 mm 
470*370*764 mm 
Unit must be vented outside when in Air Cooling and 
Heating mode. 
For the purposes of EU regulation EN12102 this is a local 
air conditioner and produces less than 65dB(A) sound 
energy. 