User Manual
TECHNICAL SPECIFICATION 
40 
 Model 
iQool9PLUS 
iQool12PLUS 
Rated voltage and frequency (Ph-V-Hz) 
1Ph/220-240V~/50Hz 
1Ph/220-240V~/50Hz 
Fuse Required 
13A 
13A 
Mode 
Cooling 
Heating 
Cooling 
Heating 
Rated capacity (W) 
2760 
(800~3500) 
2900 
(1000~3800) 
3660 
(800~4300) 
3940 
(800~4500) 
Power input (W) 
620 
(200~1450) 
660 
(200~1550) 
966 
(240~1600) 
1010 
(240~1750) 
Current input (A) 
3.8 (1.2~6.5) 
3.7 (1.2~7.0) 
5.4 (1.2~7.2) 
4.5 (1.2~8.0) 
SEER/SCOP(W/W) 
8.5/A+++ 
4.6/A++ 
8.5/A+++ 
4.6/A++ 
Nominal load (kW) 
2.7 
2.2 
3.6 
2.7 
Balance point temperature heating (
o
C) 
/ 
-7 
/ 
-7 
Min. outdoor operating temperature (
o
C) 
/ 
-15 
/ 
-15 
Thermostat-off mode (W) 
25 
25 
Standby mode (W) 
2 
2 
Off mode (W) 
0 
0 
Annual consumption (kW) 
111 
670 
148 
822 
Copper Pipe Type length 
5m 
5m 
Liquid side / Gas side (mm/inch) 
6.35 (1/4) + 9.52 (3/8) 
6.35 (1/4) + 9.52 (3/8) 
Max. refrigerant pipe length 
25m 
25m 
Max. elevation 
10m 
10m 
Interconnecting Cable 
4×1.0mm² 
4×1.5mm² 
Fuse Rating 
4A on indoor PCB 
4A on indoor PCB 
Moisture Removal (L/h) 
1.0 
1.2 
Built In Ioniser 
No 
No 
Indoor
Air Flow (m
3
/h) 
850 
850 
Dimensions (W*D*H) (mm) 
883 x 195 x 310 
883 x 195 x 310 
Packaging (W*D*H (mm) 
964 x 262 x 375 
964 x 262 x 375 
Net / Gross weight (Kg) 
10.5 / 13 
10.5 / 13 
Noise – Sound pressure level (dB/A) 
24~43 
24~43 
Noise – Sound power level (dB/A) 
34~53 
34~53 
Outdoor
Dimension (W*D*H) (mm) 
795 x 305 x 549 
795 x 305 x 549 
Packaging (W*D*H) (mm) 
852 x 358 x 600 
852 x 358 x 600 
Net / Gross Weight (Kg) 
25 / 28 
28 / 33 
Noise – Sound pressure level (dB/A) 
53 
53 
Noise – Sound power level (dB/A) 
62 
62 
Refrigerant type/weight 
R32/570g 
R32/800g 
Defrost mode 
Automatic defrosting 
Automatic defrosting 
Applicable climate types 
Cooling (15
o
C – 53
o
C) 
Heating (-15
o
C – 30
o
C) 
Cooling (15
o
C – 53
o
C) 
Heating (-15
o
C – 30
o
C) 
Due to continuous product development process specification may change.  
These units contain a gas governed by F-Gas regulations. The gas must be 
handled by qualified F-Gas engineers.