User Manual
INSTALLATION GUIDE 
30 
INFORMATION REGARDING THE INSTALLATION OF THE INDOOR UNIT 
INSTALLING THE REAR PANEL 
1.  Always mount the rear panel horizontally. 
Due to the water tray within the indoor unit 
we would advise that the outlet of the water 
tray should be fractionally lower when 
installing as this will aid drainage of the 
condensate collected. 
2.  Fix the rear panel on the wall with screws. 
3.  Be sure that the rear panel has been fixed 
firmly enough to withstand the weight of an 
adult (60Kg), furthermore the weight should 
be evenly shared by each screw. 
INSTALLING THE PIPING HOLE 
1.  Make the piping hole (65mm diameter) in the wall at 
a slight downward slant to the outdoor side (To aid 
drainage of the condensate). 
2.  Insert the piping-hole sleeve into the hole to prevent 
the connecting piping and wiring from been damaged 
when passing through the hole. 
The piping can be lead out on the right, left or directly behind the indoor unit as seen in fig. 1. 
Please cut off the pipe hole guards if you are changing the pipe position. The unit also features 
alternative guards for more pipe positioning. 
Make sure that the drain pipe is underneath the pipelines. (Fig.3) (When the drain pipe passes 
the room interior, some condensed water might occur to its surfaces if the humidity is very high). 
Tidy up the copper pipes, electrical cables and water drains and pass them through the wall hole 
drilled earlier (fig.2). 
Hang the mounting slots of the indoor unit on the wall mounting bracket making sure is tight in 
place (fig.3) so that the hooks at the bottom of the indoor unit match the hooks of the wall 
mounting bracket (fig.4)
65mm 