User Manual
11  
NOTE:    
• Make sure the filter is securely locked. Otherwise, it 
would loosen and cause dangerous. 
• When activated carbon filter attached, the suction 
power will be lowered. 
Filters for eiQCANOPY52s/BL/W Filters for eiQCANOPY70s/BL/W 
Grease filter eiqgf7628  Grease filter – eiqgf7628 
Carbon filter - eiqmidcarbon  Carbon filter – eiqmidcarbon 
BULB REPLACEMENT 
The bulb must be replaced by the manufacturer, its service agent or similarly qualified 
persons. 
Always switch off the electricity supply before carrying out any operations on the 
appliance. When handling bulb, make sure it is completely cool down before any direct 
contact to hands. 
When handling globes hold with a cloth or gloves to ensure perspiration does not 
come in contact with the globe as this can reduce the life of the globe.  
Before changing the lights, make sure that the appliance is plugged off.  
• Protect against danger when changing lights, such as wearing gloves. 
CHANGING THE LIGHTS 
1.  Remove the grease filter. 
2.  Put one hand into the cavity to gently push out the LED light, and use the other 
hand to grab the light and pull it out, and then pull out the light cable.  
3.  After changing the lamp, plug in the lamp cable, and put the lamp into the lamp 
hole. 
ILCOS D code for this lamp is: DBR-2/65-H-64 
• LED modules– round lamp 
• Max wattage: 2×2 W 
• Voltage range: AC 110-240V 