• The appliance must be placed in a room without sources of ignition (for example: open
ames, an operating gas appliance or an operating electric heater).
• R290 refrigerant gas complies with European environmental directives.
• R290 has a low GWP (Global Warming Potential) of 3.
• The ECOSILENT8 / 8E contains about 220 g of R290 refrigerant gas.
• The ECOSILENT10 / 10E contains about 280 g of R290 refrigerant gas.
• Do not use or store in an unventilated space with an area smaller than 10.6 m
2
per unit
(ECOSILENT8 / 8E) or 13.4 m
2
per unit (ECOSILENT10 / 10E).
• The room must be such as to prevent stagnation of possible leaks of refrigerant gas as
there could be a danger of re or explosion should the refrigerant come into contact
with electric heaters, stoves or other sources of ignition.
• Refrigerant gas may be odourless.
• Do not use the product and contact the retailer for advice, if damage has occurred to
the unit which may have compromised the refrigerant system.
• Any repairs or maintenance must only be carried out on the unit by a suitably qualied
engineer. Before opening and servicing the unit the authorised engineer must be in
possession of a copy of the manufacturer’s service manual and must follow the safety
information contained within it to ensure all hazards are minimized.
• The refrigerant system should not be perforated or punctured.
Energy Saving and Unit Safety Protection Tips
• Do not cover or restrict the airow from the outlet or inlet grills.
• For maximum performance the minimum distance from a wall or objects should be
50cm.
• Keep the lters clean. Under normal conditions, lters should only need cleaning once
every three weeks (approximately). Since the lters remove airborne particles, more
frequent cleaning maybe necessary, depending on the air quality.
• For the initial start-up set the fan speed to maximum and the thermostat to 5 degrees
lower than the current room temperature. After, set appliance to your desired
settings.
• To protect the unit, we recommend not using the cooling function when the ambient
temperature is higher than 35
o
C.