TROUBLESHOOTING 
Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing 
injuries and property damage. Only use it as directed in this user manual and only perform operations advised here. 
Problems  
Reasons  
Solutions  
The air 
conditioner does 
not work. 
There is no electricity.  
Turn it on after connecting it to a socket with 
electricity. 
The display shows "E7".  
Discharge the water inside.  
The ambient temperature is too low or 
too high 
Only use to use the machine within temperature 
range of 7-35⁰C (44-95⁰F). 
In cooling mode, the room temperature is 
lower than the desired temperature 
Change the desired temperature.  
In dry mode, the ambient temperature is 
low.  
The ambient temperature must be above 17 ⁰C.  
(62 ⁰F).  
The cooling 
effect is not good 
There is direct sunlight.  
Use curtains to reduce the direct sun heat 
Doors or windows are open; there are a 
lot of people; or in cooling mode, there 
are other sources of heat (e.g. fridges) 
Close doors and windows; increase air 
conditioning power 
The filter screen is dirty.  
Clean or replace the filter screen.  
The air inlet or outlet is blocked. 
Clear obstructions; make sure venting is correct as 
described in this user manual and hose is not bent  
Loud Noise 
The air conditioning is not placed on a flat 
surface. 
Put the air conditioning on a flat and hard place 
(to reduce noise).  
Compressor does 
not work. 
Overheat protection starts.  
Wait for 3 minutes until the temperature is 
lowered, and then restart the machine.  
The remote 
control does not 
work. 
The distance between the machine and 
the remote control is too far. 
Let the remote control get close to the air 
conditioner, and make sure that the remote 
control directly faces the receiver.  
The remote control is not aligned with 
the receiver. 
Batteries are dead.  
Replace batteries.  
Others 
No refrigerant or there is very little 
refrigerant 
Refer to Service Centre (check leakage, wielding, 
vacuum pump, charge refrigerant according to 
name plate) 
Anti-freezing protection  
Waiting for defrosting.  
Function will recover automatically. No user input 
needed. 
High pressure protection  
After inside gas pressure comes down, it will 
function normally. No user input needed 
If problems not listed in the table occur or recommended solutions do not work, please contact the service 
centre. 
ERROR CODES  
CODE 
CAUSE 
SOLUTION 
dH 
Unit in dry mode 
Not a fault, no action required. 
E4 
Room temperature sensor error 
Check to ensure filters are clean, vent pipe is not 
restricted, and room temperature is within 
operational range. 
E2 
Coil temperature sensor error 
E7 
Water full alarm 
Empty the water tank 
MODE LIGHT 
FLASHING 
Cool / dry / heating mode, the 
compressor has not started, the 
mode light will flash. This is normal 
The unit will start operation when the 
protection period has finished (approx. 3 
minutes) 
dp_fault_freezefault 
(in app) 
The unit has entered defrost mode.  
Leave the unit to defrost. Once the unit has 
defrosted, normal operation will resume.  