USER MANUAL EAP300PM2.5HC Thank you for choosing electriQ Please read this user manual before using this innovative Air Purifier and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY INSTRUCTIONS 3 AIR PURIFIER DIAGRAM 5 ABOUT YOUR AIR PURIFIER 6 INFORMATION ON INDOOR POLLUTANTS 7 OPERATION INSTRUCTIONS 8 BEFORE FIRST USE 8 CONTROL PANEL 9 FRONT DISPLAY 10 CARE AND MAINTENANCE 11 CLEANING THE PRE_FILTER AND FILTER HOLDING AREA 11 CHANGING THE FILTERS 11 CLEANING THE AIR QUALITY SENSOR 12 CLEANING THE CASE 12 CLEANING THE FILTER COVER AND CLEAN AIR OUTLET 12 TECHNICAL SPECIFICATION 13 TROUBLESHOOTING 13 SUPPORT 14 2
SAFETY INSTRUCTIONS Important! • Carefully read the instructions before operating the unit. • This appliance is for indoor use only. • This unit must only be connected to a 220-240V / 50Hz outlet. • Installation must be in accordance with regulations of the country where the unit is used. • If you are in any doubt about the suitability of your electrical supply, have it checked and, if necessary, modified by a qualified electrician. • This air purifier has been tested and is safe to use.
• Avoid removing the power cord from the socket whilst the unit is still in operation. This could cause electrical damage. • Never use the power supply as a switch to start and turn off the air purifier. Use the provided ON/OFF button located on the control panel. • Always place the unit on a dry and stable surface. • The use of accessory attachments that have not been approved by the appliance manufacturer is not recommended, as this may result in fire, cause an electric shock and/or cause personal injury.
AIR PURIFIER DIAGRAM Air Outlet Air Quality Indicator Handle Air Quality Sensor Air Inlet Back Cover Power Cord Ambient Light Sensor HEPA Filter Activated Carbon Filter Pre-Filter Air Inlet Panel 5
ABOUT YOUR AIR PURIFIER The EAP300PM2.5HC provides multiple stages of air purification using professional air filtration technologies. This unit features an advanced HEPA and activated carbon filters for improved air filtration. • • • The Pre-filter is used for removing large particles like hair and dust. Antibacterial HEPA filter to remove 99.9% of airborne particles of 0.25 micrometres or larger.
INFORMATION ON INDOOR POLLUTANTS VOC (Volatile Organic Compound): VOCs come from motor vehicle exhausts, gasoline vapour, pollutants such as formaldehyde, ammonia and many other common and chemical solvents such as paints and glues, or can be a by-product of mould growth. VOCs cause irritation to the eyes and or nose as well as causing headaches, nausea and even potential damage to the central nervous system.
OPERATION INSTRUCTIONS BEFORE FIRST USE: 1) Unpack the appliance and remove the filter cover from the rear of the unit, by gently pulling the Air inlet panel back and then lifting off the unit. 2) Remove the three filters from the rear of the unit. The pre filter should be gently freed from the slots holding it in position, then the HEPA and Carbon filter will slide out.
CONTROL PANEL SPEED TIMER MODE DISPLAY/LOCK RESET ON/OFF Press to turn the appliance on and off. ON/OFF SPEED TIMER MODE Press to change between the four fan speeds. The indicators will show the currently selected fan speed. When all three indicators are on, the unit is in Turbo mode. With the unit turned on, repeatedly press the timer button to select in how many hours it should turn off. The duration can be set between 1 and 7 hours in 1 hour increments.
FRONT DISPLAY The unit utilises a PM2.5 sensor to measure the air quality. When turning on the unit will take around 90 seconds before showing the air quality on the screen. The front indicator will alternate between showing the air quality, humidity and temperature. The display also illuminates to show a visual representation of the air quality.
CARE AND MAINTENANCE • Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. • When the unit is not in use for long periods, it is advisable to remove the plug from the power socket. • Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit.
CLEANING THE AIR QUALITY SENSOR • Remove the cover from the sensor, checking for any signs of blockage in the holes. Any blockages should be removed using a soft brush. • Wipe the sensor and air inlet/outlets with a damp cotton bud. It should then be dried by wiping with a dry cotton bud before replacing the cover. For optimal performance the sensor should be cleaned every two months. CLEANING THE CASE • • • • Only use tepid water and a mild detergent on a soft cloth. Do not use bleach or abrasives.
TECHNICAL SPECIFICATION Input power Rated power Net Weight Gross Weight Dimensions Fan speeds Airflow 220-240V, 50/60Hz 30 W 7 Kg 8.8 Kg 410 x 210 x 635mm Low / Medium / High / Turbo 310 m3/h TROUBLESHOOTING ISSUE CHECK Check that the unit is plugged in Not working Abnormal Smells Pollutants not removed and loud noise when running Ensure that the filters and filter cover are correctly installed. Check if the filters are clean. Replace the filters. Check if the filters are clean.
electriQ UK SUPPORT www.electriQ.co.uk/support Please, for your own convenience, check the troubleshooting guide before calling the service line. If the unit still fails to operate call: 0871 620 1057 or complete the online form Office hours: 9AM - 5PM Monday to Friday www.electriQ.co.uk Unit J6, Lowfields Way Elland, West Yorkshire HX5 9DA Do not dispose this product as unsorted waste. Collection of such waste must be handled separately as special treatment is necessary.