9
Humidity set to 60% RH; great for personal comfort and applications where 50% RH is considered
too dry
Humidity set to 70% RH; ideal for unoccupied properties or where economical run is needed
without the need to go drier than 70% RH
Other features and Indicators
Tank Full Light
Red light will be on and the unit will beep when the tank is ready to be emptied, or when the
tank is removed or not replaced in the proper position. The water level control switch shuts off
the dehumidifier when the tank is full, or when the tank is removed or not replaced in the proper
position. Empty and replace to resume operation.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in
to defrost mode
When the unit is running in a room with temperature between 5
o
C and 12
o
C, it enters the defrost
mode about once every 30 minutes.
When the unit is running in a room with temperature between 12⁰C and 20⁰C, it enters the
defrost mode about once every 45 minutes.
Normal operation will resume after defrost mode.
Humidistat control and fan/ compressor operation
When the selected humidity is 2% lower than the user selected humidistat setting; the
dehumidifiers compressor will be shut off automatically but the fan will still move to ensure air is
not stale in the room. The unit will use only a minimal amount of energy in fan mode.
When the humidity is equal or higher than user selected humidity the compressor will restart
once the 3 minutes delay compressor protection expires.
Auto-Restart (on some models)
If the unit stops off unexpectedly due to the power cut, it will restart with the previous function
selected automatically when the power resumes.
Power
After the unit has stopped, it is not recommended to resume operation for at least 10 minutes.
This is to protect the compressor. Operation can resume after this period lapses. When the unit is
restarted there is a 3 minutes delay before compressor will start.
Lightweight Portable Design on castors
The dehumidifier is built to be compact and lightweight. The castors on the bottom of the unit
make it easy to move from room to room.
Your CD12LE/CD20LE dehumidifier is an advanced micro-CPU controlled device able of
self-diagnostics. The LCD display may also show the error and protections codes.