USER MANUAL PREMIUM DEHUMIDIFIER WITH DIGITAL HUMIDISTAT AND AIR PURIFIER CD20L - 20L litres per day Thank you for choosing electriQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www.electriQ.co.
CONTENTS SAFETY 3 ENERGY SAVING 5 QUICK SAFETY GUIDE 6 INSTALLATION 7 FEATURES 7 PARTS 8 CONTROL PANEL 9 QUICK REFERENCE GUIDE 11 OTHER FEATURES AND INDICATORS 13 POSITIONING THE DEHUMIDIFIER 14 WATER DRAINAGE 14 CARE AND MAINTENANCE 15 FREQUENTLY ASKED QUESTIONS 16 TROUBLESHOOTING 17 TECHNICAL SPECIFICATION 18 SUPPORT 18 2
SAFETY INSTRUCTIONS IMPORTANT • Carefully read the instructions before operating the unit. • This appliance only intended for use in an indoor domestic environment. Any other use is not recommended by the manufacturer and may cause fire, electrical shock or other injuries to person or damage to property. • Rating: This unit must only be connected to an AC 220-240V / 50 Hz earthed outlet. Installation must be in accordance with the regulations of the country where the unit is used.
• A damaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard. • Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty. • Do not use the appliance for any purpose other than its intended use. • Do not tilt the unit while in use. The unit is designed to work only in a vertical position.
ENERGY SAVING AND UNIT SAFETY PROTECTION TIPS Do not cover or restrict the airflow from the outlet or inlet grills. For maximum performance, the unit should be operated at least 20 cm away from walls and 50 cm from other objects within the room. Keep the filters and grills of the appliance clean. Under normal conditions, filters and grills should only need cleaning once every three weeks (approximately).
QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER 6
INSTALLATION Remove any water from within the water tank before starting the unit. In order to save energy do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 24 hrs. TO REDUCE NOISE LEVELS: Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. The 20L entry dehumidifiers use compressor technology to extract water from the environment.
PARTS 1. 3 . 4 . Humidity indicator light 5 . Wheels 6. Louvers Handle 2. Air outlet Control Panel 7. Pre-filter/ activated Carbon filter 9. 8 . Air inlet Continuous Drain Port 11 10 . Back Cover 12 . Power cord Activated carbon filter (Optional) 8 .
CONTROL PANEL Timer/ Humidity Up Timer/ Humidity Down Humidity Indicator Timer Oscillation Mode Selection Tank Full Indicator Defrost Indicator Power Button On/ Off Indicator 9
POWER Turn the appliance on/off MODE Button Select the function of the unit between SMART / HIGH / LOW / and FAN. The LED’s next to the button will show which mode is selected. SMART MODE: The unit will default to SMART mode the first time it is switched on and remains in this mode until another program is chosen. In smart mode, it will aim for a relative humidity of 50-55%, and the fan speed will be adjusted automatically.
` TIMER Press the TIMER button to program the timer. When the timer is activated, the "TIMER" light will illuminate. Before programming the timer, ensure the timer function has not been activated (the light must be off). The following timer programs are available. DELAYED POWER-ON FUNCTION: With the appliance in standby, press the TIMER button, then use the UP and DOWN buttons to set in how many hours’ time you require the unit to start (0~24 hours).
QUICK REFERENCE GUIDE POWER BUTTON: Press to turn the unit ON/OFF. OSCILLATION BUTTON: Press once to make the louvre swing and press again to lock at 45 degrees, press again to lock at 90 degrees. Do not operate the unit if the self-opening louvers do not open on power on.
During operation the compressor will operate until the desired humidity is reached and then will stop. The economical low air purifier mode will continue to operate. The fan moves the air around the room ensuring the entire air in the room is processed and humidity correctly measured. To achieve drier air, or while drying laundry, put the unit in High mode and use the down button to select a lower desired humidity (e.g. 35-45%).
OTHER FEATURES AND INDICATORS TANK FULL LIGHT When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, the red tank full light will illuminate and the unit will beep. Empty the tank and reinsert it correctly to resume operation. AUTO DEFROST When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost mode. Following completion of the defrost mode, the unit will return to the previously operating settings.
POSITIONING THE DEHUMIDIFIER A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation of air in not restricted around the unit. Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential or small office applications and any commercial or industrial use will invalidate the warranty. 20 cm Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating environment.
NOTE: When you remove the water tank, do not touch sensors or any parts which are situated behind tank. Doing so may damage the product. Be sure to push the tank gently all the way into the unit. Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate. Do not remove any parts from the water tank or tank enclosure. The water full sensor will no longer be able to detect the water level correctly and water may leak from the water tank. 2.
NOTE: While the carbon filter is optional never run the unit without the mesh filter frame correctly inserted. 2. CLEAN THE WATER TANK Every few weeks, clean the tank to prevent growth of mould, mildew and bacteria. Partially fill the tank with clean water and add a little mild detergent. Swish it around and then empty the tank and rinse. NOTE: Do not use a dishwasher to clean the tank. After cleaning and drying, the tank must be reinserted securely into dehumidifier in order to restart operation.
TROUBLESHOOTING Issue Cause Hot or cold air Normal being Operation produced Solution When the unit is in dehumidifying mode it absorbs humid air from room and freezes it to reduce the humidity. During the cold cycle there should be cold air coming out of the unit During the defrost cycle hot dry air should be coming out of the outlet grill. Insert the plug into the socket and turn the switch on.
TECHNICAL SPECIFICATIONS Model Voltage Dehumidifying capacity CD20L-V4 1Ph, 220-240V~ 50Hz 20 L / day (at 30oC / 80%RH) Fan Speeds Power Consumption Running Amps Tank Capacity Humidity settings range 2 270W 1.2 Amps 4 litres 35%~80% IP RATING Refrigerant Airflow m3/h High / Low Pressure Max noise level dB(A) Filters Dimensions mm (WxHxD) IPX1 R290, 75 grams 180 3.2/0.7MPa 42-49 carbon (optional) 380x580x195 Weight kgs GWP 14.3 3 electriQ UK SUPPORT www.electriQ.co.
APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.