COMPRESSOR DIGITAL DEHUMIDIFIER CD10L – 10 litres per day CD20L – 20 litres per day USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www.electrIQ.co.
Contents Safety Instructions ………………..……………….. 2 Installation ………………..……………….. 4 Parts ………………..……………….. 5 Control Panel ………………..……………….. 6 Quick reference guide ………………..……………….. 7 Positioning ………………..……………….. 10 Water Drainage ……………………………….. 11 Care and Maintenance ………………..……………….. 11 Troubleshooting ………………..……………….. 13 Technical Data ………………..………………..
SAFETY INSTRUCTIONS Important • Carefully read the instructions before operating the unit • This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used.
• Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operating it. • Do not store or use gasoline, petrol, paint, solvents or other flammable vapours or liquids in the vicinity of this dehumidifier or any other appliance.
Installation Remove any water from the water tank before starting the unit. In order to save energy, do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 24 hrs. To reduce noise levels: Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. CD10L & CD20L dehumidifiers use compressor technology to extract water from the environment.
PARTS CD10L CD20L 1. Front Case 2. Dry Air Outlet 3. Handle 4. Control Panel 5. Air Inlet/ Filter housing 6. Back case 7. Water Tank 8. Wheels / Feet 9.
CONTROL PANEL CD10L LED Indicators 1. Water Full – Red 2. Compressor on – Green 3. Defrost – Green 4. Timer – Orange Buttons A. Power on/ off B. Down (Humidity Settings) C. Up (Humidity Settings) D.
CD20L LED Indicators 1. 2. 3. 4. 5. 6. Power indicator – Green Timer – Orange Water tank full – Red Fan speed low – Green Fan speed high – Green Laundry mode - Green POWER Turn on/off the appliance Timer When the unit is on standby, press the timer button to set the delay until it turns on. When the unit is on, press the timer button to set the delay until it turns off. Press the timer button to select the delay time you require in hours cycling from 0 to 24 hrs.
Humidity Level & Timer 2 digit display The led indicator performs the following functions: 1. When the unit is plugged in, it will indicate the room humidity level 2. When the humidity level is selected, it will indicate the set humidity 3. When the start / stop timer is programmed will show the set timer Notes: When humidity level is outside the normal operational parameters will show LO/HI. If ambient humidity is lower than 35%, it will show “LO” If ambient humidity is higher than 95%, it will show “HI”.
Other features and Indicators Tank Full Light Red light will be on and the unit will beep when the tank is ready to be emptied, or when the tank is removed or not replaced in the proper position. The water level control switch shuts off the dehumidifier when the tank is full, or when the tank is removed or not replaced in the proper position. Empty and replace to resume operation.
Positioning the dehumidifier A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation of air in not restricted around the unit. Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential / small office applications and any commercial or industrial use will invalidate the warranty. Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating environment.
NOTES: When you remove the bucket, do not touch sensors or any parts which are situated behind tank. Doing so may damage the product. Be sure to push the tank gently all the way into the unit. Banging the bucket against anything or failing to push it in securely into place may cause the unit not to operate. Do not remove any parts from the water tank or tank enclosure. The water full sensor will no longer be able to detect the water level correctly and water may leak from the water tank. 2.
1. Clean the Grille and Case Use water and a mild detergent to clean the washable antibacterial mesh filters. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock and can lead to the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a soft damp cloth or kitchen towel.
End of Season Maintenance: : 1. Empty and clean the water tank. 2. Clean the unit and the filters as per cleaning procedure above. 3. Coil the power cord at the back of the unit 4. Cover the unit and keep it in a dry place. Frequently Asked Questions Why doesn’t the dehumidifier seem to extract much water if the temperature is low? This is a compressor dehumidifier which works best in temperatures above 15⁰C.
Troubleshooting Issue Cause Solution Hot or cold air Normal Operation When the unit is in dehumidifying mode it absorbs humid air from room and being freezes it to reduce the humidity. produced During the cold cycle there should be cold air coming out of the unit During the defrost cycle hot dry air should be coming out of the outlet grill. Unit does not Is the plug properly inserted operate in the socket? Front louvres Insert the plug into the socket and turn the switch on.
Technical data Model Voltage Dehumidifying capacity CD10L CD20L 220-240V~50Hz 220-240V~50Hz 10 L / day (at 30⁰ C / 80%RH) 1 240 W 1.2 Amps 2 litres 30%~90% R134a, 65 grams 150 2.6 / 1.0 MPa ≤42 1.8 meters 276x185x480 20 L / day (at 30⁰ C / 80%RH) 2 380 W 2 Amps 5 litres 30%~90% R134a, 250 grams 150 / 200 (Low/ High) 2.6 / 1.0 MPa ≤47 1.
ElectrIQ UK SUPPORT www.ElectrIQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains? 3. Is the fuse OK? 4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. 5. Check if the water tank is full. Is the tank correctly inserted back into the unit? 6.