USER MANUAL 12 LITRE COMPRESSOR DEHUMIDIFIER WITH DIGITAL HUMIDISTAT CD12P Thank you for choosing electriQ. Please read this user manual before using this innovative Dehumidifier and keep it safe for future reference Visit our page www.electriQ.co.
CONTENTS SAFETY INSTRUCTIONS 2 INSTALLATION 5 PARTS 6 CONTROL PANEL 7 QUICK REFERENCE GUIDE 8 POSITIONING 11 WATER DRAINAGE 12 CARE AND MAINTENANCE 12 TROUBLESHOOTING 14 TECHNICAL DATA 15
SAFETY INSTRUCTIONS IMPORTANT Carefully read the instructions before operating the unit This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property. Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with regulations of the country where the unit is used.
R290 refrigerant gas complies with European environmental directives. R290 has a low GWP (Global Warming Potential) of 3. The CD12P contains about 55g of R290 refrigerant gas. Do not use or store the appliance in an unventilated space with an area smaller than 2.6m2 per unit.
QUICK VISUAL SAFETY GUIDE ON WHERE OR WHEN NOT TO USE YOUR DEHUMIDIFIER Exposed to the weather outdoors Near water If the power cable wires are frayed or cut Where small children may be left unattended If an extension lead may become overloaded Where the power cable may be damaged On a slope or uneven surface Where there is risk of fire or close to a naked flame Where it may be damaged by chemicals Where there is a risk or interference by foreign objects This product is not made for DIY repair I
INSTALLATION Remove any water from within the water tank before starting the unit. In order to save energy do not open windows or doors while the unit is running. Place the unit on a hard / flat surface. On first use run the unit continuously for 24 hrs. TO REDUCE NOISE LEVELS: Place a piece of carpet or a rubber mat under the unit to reduce any vibrations while the unit is running. The CD12P dehumidifier uses compressor technology to extract water from the environment.
PARTS Control Panel Handle Air outlet Humidity indicator light Wheels Air inlet Pre-filter/activated Carbon filter Continuous Drain Port Water tank Power cord OPTIONAL ACCESSORIES HEPA Filter Activated carbon filter 06
CONTROL PANEL Humidity Indicator Down Up Mode HUMIDITY INDICATOR LIGHT MODE SMART AIR PURIFIER OPERATION TIMER TANK FULL DEFROST Power Timer MODE On/Off SMART AIR PURIFIER Water full indicator OPERATION TANK FULL DEFROST Defrost indicator POWER POWER Button Turn the appliance on/off MODE Button Select the function of the unit between SMART and FAN modes. The LED’s next to the button will show which mode is selected.
TIMER DEFROST TANK FULL TIMER Press the TIMER button to program the timer. When the timer is activated the "TIMER" light will be illuminated. Before programming the timer, ensure the timer function has not been activated (the light must be off). The following timer programs are available. DELAYED POWER-ON FUNCTION: With the appliance in stand-by, press the TIMER button, then use the UP and DOWN buttons to set in how many hours time you require the unit to start (1~24 hours).
QUICK REFERENCE GUIDE POWER TIMER Power Button: Press to turn the dehumidifier on and off. Timer: Press the timer button, then use the duration of the timer (1-24 hrs, start/ stop timer). buttons to adjust the If set while the unit is running: The number will represent the number of hours the unit will operate before turning off. This will not be affected if the unit enters defrost mode or the tank is emptied and reinserted.
OTHER FEATURES AND INDICATORS TANK FULL LIGHT When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, the red tank full light will illuminate and the unit will beep. Empty the tank and reinsert it correctly to resume operation. AUTO DEFROST When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost mode. Following completion of the defrost mode, the unit will return to the previously operating settings.
POSITIONING THE DEHUMIDIFIER A badly positioned dehumidifier will have little effect. In positioning the dehumidifier please ensure circulation of air in not restricted around the unit. Allow at least 20 cm space around the unit. This dehumidifier is designed only for indoor residential or small office applications and any commercial or industrial use will invalidate the warranty. Use in an enclosed area for maximum efficiency. Close all doors, windows to create an effective operating environment.
WATER DRAINAGE When the water tank is full, the unit will stop automatically. When this happens the TANK FULL red light will show on the control panel. NOTE: Only empty the water tank when it is full or before moving or storing the unit. There are two ways to dispense collected water. 1. USE THE TANK When the tank is full, the unit will automatically stop running, and the Tank Full indicator will flash. Slowly pull out the tank. Grip the tank by its handle securely, and carefully pull it out.
CARE AND MAINTENANCE Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When it is not in use for long periods it is advisable to remove the plug from the power socket. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit. 1. CLEAN THE GRILLE AND CASE Use water and a mild detergent to clean the washable mesh filters. Do not use bleach or abrasives. Do not splash water directly onto the main unit.
FREQUENTLY ASKED QUESTIONS Why doesn't the dehumidifier seem to extract much water if the temperature is low? This is a compressor dehumidifier which works best in temperatures above 15oC. If the temperature is low and the air is dryer than the setting on the humidistat the unit will not extract water. If you want to use a dehumidifier for outside buildings, unheated properties, boats or garages please check our desiccant range.
Technical data Model Voltage Dehumidifying capacity Fan Speeds Power Consumption Running Amps Tank Capacity Humidity settings range IP RATING Refrigeran Airflow m3/h High / Low Pressure Max noise level dB(A) Filters Dimensions mm (WxDxH) Weight kgs GWP CD12P 1Ph, 220-240V~ 50Hz 12L / day (at 30oC / 80%RH) 1 185W 0.81 Amps 2.5 litres 35%~80% IPX1 R290, 55 grams 135 3.2/0.7MPa 39 Carbon (Optional) HEPA (Optional) 349x491x200 10.5 3 DDisposal: Do not dispose this product as unsorted waste.
electriQ UK SUPPORT www.electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains? 3. Is the fuse OK? 4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. 5. Check if the water tank is full. 6.