USER MANUAL PORTABLE AIR CONDITIONER WITH HEATPUMP AND WIFI AIRFLEX15W Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY INSTRUCTIONS 3 FEATURES AND PARTS LIST 5 INSTALLATION 6 CONTROL PANEL AND SETTINGS 9 CONNECTING THE AIR CONDITIONER TO WIFI 12 OPERATION MODE 13 DUAL DUCTING THE UNIT 17 WATER-DRAINAGE 18 MAINTENANCE 19 TROUBLESHOOTING 20 APPENDIX 21 Page 2 of 22
SAFETY INSTRUCTIONS Important! • Carefully read the instructions before operating the unit. • This Air Conditioner has an IP24 rating. It is designed mainly for indoor use but will stand up to outdoor use being protected against light rain and splashing. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used.
• • • • • • • • • • • R290 has a low GWP (Global Warming Potential) of 3. The air conditioner contains about 235 g of R290 refrigerant gas. Do not use or store in an unventilated space with an area smaller than 11.3m2 per unit. The room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
FEATURES AND PARTS LIST FEATURES ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ Part of the electriQ range of Intelligent Air Conditioning products Cooling, Heating and Dehumidifying for use all year round.
INSTALLATION Warning:Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface. UNPACKING YOUR NEW AIR CONDITIONER Open the box and remove the outer carton by sliding it upwards from the base.
ATTACHING THE HOSE 1. Clip the hose connector and front vent to the sides of the unit (after removing the hose from storage) 2. Insert the hose and rotate it firmly into the adapter 3. To remove the hose twist it in the opposite direction. Note: To install the hose for heat mode please remove the hose, the hose connector and front vent from the unit and re fit on the opposite sides. The process should be reversed to put the unit back in to cooling mode.
INSTALLATION OF WINDOW KIT Partially open the window and then fix the window kit to the window horizontally or vertically. Keep at least 50 cm from any objects and the air inlets grills on the side of the unit. Clip the other end of the hose with the fishtail adapter to the air outlet of the window slider. Make sure the unit is upright and there are no obstructions to the air inlet and outlet grills. The window kit is only designed to be installed with sliding or sash windows and doors.
CONTROL PANEL AND SETTINGS This portable air conditioner boasts the functions: cooling, heating, and dehumidify. The fan has three speeds: high, medium and low Temperature range settings are: 16 – 310C. The LED screen is able to display the temperature set, fault codes, diagnostic and protective codes.
(1) STANDBY Button Press this button to turn the unit on and enter cooling mode. Press again and the unit will switch off. (2) TEMP + Button These are used to increase the desired temperature In cooling mode, the temperature can be set between 16 – 31°C In heating mode, the temperature can be set between 16 – 31°C (3) FUNCTION Button Press this button to choose between the Cooling, Heating, and Dehumidifying modes.
(7) to (9) FUNCTION INDICATORS An LED will illuminate to show which mode the unit is currently in. This can be changed between Dehumidify (7), Cooling (8) and Heating (9) using the Function Button (3) (10) IR REMOTE SENSOR Receives infra red signals from the supplied remote control (11) to (14) FAN SPEED INDICATORS An LED will illuminate to show which fan speed the unit is currently set to. This can be changed between High (11), Medium (12), and Low(14) using the fan speed button (6).
REMOTE CONTROL Power Speed Temp + Temp Mode Timer To enter / exit standby Mode. Fan speed selection (N/A in dehumidification mode) Increase desired temperature in 1 degree increments Decrease desired temperature in 1 degree increments Change between Heating, Cooling, Dehumidifying, fan and auto modes. Set the timer. For more information see the Timer section on Page 10.
OPERATION MODES The electriQ Airflex 15 is the most flexible fully featured air conditioner on the market. When combined with a gravity flap, the air conditioner can be used in spaces where there is not enough space to fit a standard portable air conditioner, making it the perfect choice for Server Rooms, Small office spaces etc. The Airflex 15 can be placed outside the room to cool, on balconies, corridors, mezzanines etc.
The hose can be vented via a tilted window, a door or wall aperture. Make sure that no warm air from outside can enter the room. Set the function to “COOLING”. Set the target temperature using the temperature control. The target temperature range is selectable between 16°C and 31°C. The unit must only be used in an ambient temperature of up to 32°C. Note: After switching on, the compressor will only start after a 3 minute delay. For full cooling effect please allow a further 10 minutes of operation.
HEATING Be aware that on very cold days the unit should only be operated indoors. When the outside temperature gets colder, it will take longer to heat the room. We recommend that when you have achieved the desired temperature to leave the unit running on thermostatic control and it will maintain the temperature set very economically. To improve the heating effect we recommend you set the unit up for continuous drainage.
HEATING WHEN AC IS PLACED OUTDOORS (DUCTING THE HOT AIR INTO THE ROOM) Connect the air hose to the hot air outlet of the air conditioner after exchanging the grills if necessary. The air hose will send hot air into the room, while the front grills will expel cold air. The unit is placed outside the room to be heated. Outdoor operation is ideal for the autumn period in which outside temperatures do no fall below 10°C.
DUAL DUCTING THE UNIT The Airflex 15 also supports dual ducting in both cooling and heating modes. This means the unit can operate with two hoses connected at the same time. To do this the unit should be set up with a compatible gravity flap for sending cooled / heated air into the room, with a second pipe connected sending the waste air outside. I.e. in the winter the unit could duct the hot air into the room while ducting cold air outside, with the unit inside to increase performance.
WATER-DRAINAGE This model is an advanced self-evaporative air conditioner, which reduces the need to empty the water tank in cooling mode. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. As such for cooling mode, to ensure the unit runs at maximum efficiency, we would advise for continuous drainage not to be used.
MAINTENANCE CLEANING Please shut off the unit and unplug from the mains before cleaning or performing any maintenance CLEAN THE SURFACE Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. AIR FILTER CLEANING a) Clean the air filter every 2 weeks. If the air filter is blocked with dust, the unit’s performance will be significantly affected.
TROUBLESHOOTING Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm. Problem Reason Solution Ensure the unit is plugged in and attempt No power supply The unit does not work The unit does not seem to perform. Water-full indicator (E4) Timer function is active Room temperature too low or too high In direct sunlight Windows or doors open. Large amount of people or a heat source in the room.
APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.
electriQ UK SUPPORT www.electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate call: 0330 390 3061 or complete the online form 1. 2. 3. 4. Has the unit been standing upright for at least 2 hours? Is the unit plugged into the mains? Is the fuse OK? Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. 5. Check if the water tank is full.