Service manual
5-6
PERFORMANCE DATA & PRESSURE CURVES       
SM DLF 1-A.1 GB
5.2  DLF 35 / ONG3-35 DCI
5.2.1 Cooling Capacity (kW)
ID COIL ENTERING AIR DB/WB TEMPERATURE [C0]
OD COIL ENTERING AIR 
DB TEMPERATURE [C0]
DATA 22/15 24/17 27/19 29/21 32/23
 -10 - 20 
(protection range)
TC 80 - 110 % of nominal
SC 80 - 105 % of nominal
PI 25 - 50 % of nominal
25
TC 3.38 3.60 3.83 4.05 4.27
SC 2.76 2.81 2.87 2.93 2.98
PI 0.75 0.76 0.78 0.79 0.80
30
TC 3.22 3.44 3.66 3.88 4.11
SC 2.69 2.74 2.80 2.86 2.91
PI 0.83 0.85 0.86 0.88 0.89
35
TC 3.06 3.28 3.50 3.72 3.94
SC 2.62 2.67 2.73 2.79 2.84
PI 0.92 0.94 0.95 0.96 0.98
40
TC 2.89 3.12 3.34 3.56 3.78
SC 2.55 2.60 2.66 2.72 2.77
PI 1.01 1.02 1.04 1.05 1.07
46
TC 2.70 2.92 3.14 3.36 3.58
SC 2.46 2.52 2.58 2.63 2.69
PI 1.11 1.13 1.14 1.16 1.17
LEGEND
TC  –  Total Cooling Capacity, kW
SC –  Sensible Capacity, kW
PI  –  Power Input, kW
WB  –  Wet Bulb Temp., (
o
C)
DB  –  Dry Bulb Temp., (
o
C)
ID  –  Indoor
OD  –  Outdoor
5.2.2  Capacity Correction Factors (Cooling)
Cooling Capacity Ratio Vs.Outdoor Temperature
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
20 25 30 35 40 45
Outdoor Temperature DB [deg C]
Capacity Factor