DISPOSAL OF OUTDOOR UNIT CONDENSED WATER 
In case of using a drain elbow, the unit 
should be placed on a stand at least 3 cm 
high. 
Install the hose with a downward to allow 
smooth flow of draining water. 
Use 16mm I.D. tube for drainage. 
PIPES CONNECTIONS
CUTTING AND FLARING THE PIPES 
1.  Please use the pipe cutter 
for cutting the pipes. 
2.  Remove all burrs by using 
reamer. Gas leakage 
might happen If burrs are 
not removed ! 
Turn pipes edge down to 
avoid metal powder from 
entering down the pipes. 
3.  After inserting the flare 
nut into the cooper pipes, 
please make a flare. 
PIPE INSULATION 
1.  Please carry out insulation at pipe 
connection portion as mentioned in Indoor/ 
Outdoor Unit Installation Diagram. Please 
wrap the insulated piping end to prevent 
water from going inside the piping. 
2.  If drain hose or connecting pipes is in the 
room (where dew may form). Please 
increase the insulation by using POLY-E 
FOAM with thickness of 9 mm or more.