Service manual
5-17
PERFORMANCE DATA & PRESSURE CURVES
Revision Y06-02Service Manual - KN Series
5.12  KN36 / OU10-36T R410A 
5.12.1  Cooling Mode at 7.5m Tubing Connection. 
  230V : Indoor Fan at High Speed.
ENTERING AIR 
DB OD COIL (°C)
DATA
ENTERING AIR WB/DB ID COIL ( °C)
15/21 17/24 19/27 21/29 23/32
15
(1)
TC
10.22 10.59 10.84 11.10 11.26 
SC
6.35 6.62 6.88 7.05 7.18 
PI
2.37 2.37 2.38 2.38 2.40 
20
(1)
TC
9.89 10.43 10.76 11.01 11.25 
SC
6.22 6.56 6.83 7.03 7.16 
PI
2.57 2.58 2.59 2.60 2.61 
25
TC
9.36  10.10 10.62 10.95 11.21 
SC
6.06 6.43 6.78 6.98 7.11 
PI
2.78 2.80 2.82 2.83 2.85 
30
TC
8.75 9.53 10.29 10.66 10.98 
SC
5.87 6.24 6.63 6.83 6.96 
PI
3.00 3.04 
3.07 
3.09 3.12 
35
TC
8.10 8.79 
9.70 
10.19 10.67 
SC
5.58 5.98 6.48  6.67 6.80 
PI
3.23 3.29 
3.34 
3.37 3.38 
40
TC
7.37 8.02 
8.75 
9.57 10.06 
SC
5.26 5.66 6.13 6.32 6.45 
PI
3.49 3.54 3.60 3.65 3.68 
46
TC
6.39 6.99 7.69 8.49 9.15 
SC
4.85 5.19 5.59 5.78 5.91 
PI
3.81 3.87 3.96 4.01 4.06 
LEGEND
TC  –  Total Cooling Capacity, kW
SC –  Sensible Capacity, kW
PI  –  Power Input, kW
WB  –  Wet Bulb Temp., (
o
C)
DB  –  Dry Bulb Temp., (
o
C)
ID  –  Indoor
OD  –  Outdoor
(1) Marked area is below standard operating limits. For operating in low ambient 
conditions, refer to Optional Accessories (Chapter 15).
CONTENT