ELEKTRA PRO UV ® EP Series Ultraviolet Sanitizer/Clarifier System INSTALLATION INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS WARNING FOR YOUR SAFETY — This product should be installed by a professional service technician or similar person, qualified in electrical equipment installation. Improper installation and/or operation could cause serious injury, property damage or death. Improper installation and/or operation will void the limited warranty.
INSTRUCTIONS PERTAINING TO RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSON WARNING — When using this unit, basic precautions should always be taken, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. DANGER: To reduce the risk of injury, do not permit children to use this unit unless they are closely supervised at all times. 3. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. 4.
SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING When using electrical products, basic precautions should always be followed, including the following: 1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a Ground Fault Circuit Interrupter. 2. Grounding is required. The unit should be installed and grounded by a qualified service representative. 3. Install to permit access for servicing. IMPORTANT: Follow the instructions below EXACTLY and IN THE ORDER LISTED.
8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 17.0 18.0 19.0 Quartz Tube Installation 8.1 Inserting Quartz Tube 8.2 Seating Quartz Tube 8.3 Sealing Gasket Installation 8.4 Acorn Nut Installation 8.5 Leak Checking Quartz Tube UV Bulb Installation 9.1 Seat Bulb End Cushion 9.2 Install O’Rings On Bulb End 9.3 Insert Bulb Into Quartz Tube 9.4 Ballast and Bulb Caution 9.5 Install Ballast Socket On Bulb 9.6 Install Electrical Enclosure Bonnet 9.7 Plug UV Unit Into Electrical Power 9.
0.0 Forward: The Elektra® Pro UV Unit is designed for use in swimming pools, fountains, water features, waterfalls and fish ponds. It is not designed for use in potable (drinking) water installations. Use of this product in applications other than those indicated above will void your warranty and could be harmful to your health or the health of others. 1.
3.
5.3 Installing Inlet/Outlet Unions - The EP unit comes with union nuts installed on the housing. Packed with your EP unit are the remaining components necessary to complete the Inlet/Outlet unions. The clear union tail piece is used on the top union, and the solid color union tail piece is used on the bottom union. Also packed with your EP unit are two white gaskets that are used to complete the Inlet/Outlet unions. One side of the gasket is flat, the other side has a half round bead on the face.
5.6 Gluing Piping To The UV Unit - The Inlet/Outlet PVC union tail pieces are 2 inch pipe size (63mm for overseas models). Your PVC supply piping should be glued into the union tail pieces using an appropriate PVC primer and PVC cement, as recommended by your supplier. Inlet piping should be supported and should not rest solely upon the unions, to avoid breaking the unions. The installation of valves on the inlet and outlet lines attached to the UV unit is recommended.
6.0 Start-Up - Once you have completed all steps above, including (IMPORTANT) verification that the unit has no leaks anywhere, including a possible broken quartz tube damaged during transit, you are ready to start your unit up. 6.1 Start Up Circulation Pump - Once the pump is on, be sure to drain all air from your system through the air relief valve on the filter if so equipped. 6.
7.6 Remove The Quartz Tube - First make sure the quartz tube is cool. Do not handle a quartz tube until it cools. Grasp the quartz tube that is extended above the mounting gland and pull straight up to remove it from the EP unit wet chamber. The quartz tube can now be easily cleaned. 7.7 Cleaning The Quartz Tube - The quartz tube exterior can normally be cleaned by mixing a mild solution of Muriatic Acid (available at all pool supply stores)with water in a ratio of four parts water to one part acid.
9.3 Insert Bulb Into Quartz Tube - Slowly lower the bulb down into the quartz tube, until the bulb O’Rings are down inside the quartz tube. Make sure the bulb O’Rings have not become dislodged from the white ceramic on the end of the bulb while the bulb is being inserted down into the quartz tube. Re-position the bulb O’Rings if necessary. 9.4 Ballast and Bulb Caution - CAUTION: DO NOT INSTALL THE ELECTRICAL SOCKET FROM THE BALLAST TO THE FOUR PINS ON THE END OF THE BULB AT THIS TIME.
10.3 Electrical Enclosure Bonnet Removal - Follow Sec. 7.3 instructions to remove the electrical enclosure bonnet. 10.4 Steps To Follow For Bulb Replacement - Follow the steps noted for bulb removal and replacement during quartz tube removal (Sec. 7.0) and installation (Sec 9.0) to remove the old bulb and complete the installation of a new bulb. 11.
unit wet tank. It is important to maintain a chemical regiment as directed by your pool chemical supplier, however you will notice a dramatic decrease in chemical usage as one of the side benefits of the EP unit is that it attacks the chloramines that form in pool water when sanitizing chemicals are inadequate or when bathing loads are heavy. 15.
17.2 Do I Need To Turn My EP Unit Off When I Clean My Filter? - No, the flow sensing pressure switch that is part of your EP unit will automatically shut the UV bulb off until proper water flow inside the EP unit is re-established. Should you need to turn your unit off for any reason, this is accomplished by simply unplugging the EP unit from its power outlet. 17.
increase the pressure inside the EP wet chamber. A low pressure 1/2 psi pressure switch (P/N 7002315) is also available and can be installed in lieu of the 5 psi pressure switch supplied. b. The bulb has become disconnected from the bulb connector. Disconnect the power cord from the electrical outlet, open the electrical enclosure bonnet and confirm the bulb connector is firmly in place. At the same time, check all exposed wires for a possible loose connection.
b.Run your unit longer. If your unit is operating on a time clock, run the circulation pump longer to allow the EP unit to function fully. c.Clean the quartz tube. d.Replace the UV bulb if it is nearing the 9000 hour useful life. At 9000 hours of operation, the UV bulb is 60% as effective as it was when it was new. This is normal for all low-pressure type UV bulbs, which are the longest life bulbs used in this type of application. e.
ELEKTRA® PRO UV LIMITED WARRANTY Delta Ultraviolet Corporation warrants to every original Purchaser of Delta UV’s Elektra® Pro Ultraviolet Unit, that the product will be free from defects, as defined herein, for a period of Five (5) Years.
REFERENCE INFORMATION DEALER _____________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ PHONE ______________________________________________ CONTACT ____________________________________________ DATE OF INSTALLATION _________________________________ MODEL ______________________ RE-LAMP DATE _________________________ RE-LAMP DATE _______________________________ R
- NOTES - 19
4270 Promenade Way, Suite D Marina del Rey, CA 90292 310-577-1840 PHONE 310-305-9755 FAX CUSTOMERSERVICE@DELTAUV.COM IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS P/N 94-35227 Rev.