Data Sheet
Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 73 2015-08-03
[,<number>,<type>,<alphaID>][...]]]
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<idx> 1..7 Call identification number
This number can be used in +CHLD command operations
<dir> 0 Mobile originated (MO) call
1 Mobile terminated (MT) call
<stat> State of the call:
0 Active
1 Held
2 Dialing (MO call)
3 Alerting (MO call)
4 Incoming (MT call)
5 Waiting (MT call)
6 Disconnect
<mode> Bearer/tele service:
0 Voice
1 Data
2 Fax
<mpty> 0 Call is not one of multiparty (conference) call parties
1 Call is one of multiparty (conference) call parties
<number> String type (string should be included in quotation marks)
phone number in format specified by <type>.
<type> Type of address
<alphaId> String type (string should be included in quotation marks)
alphanumeric representation of <number> corresponding to the entry
found in phone book.
Parameter Saving
Mode
AUTO_SAVE
Max Response
Time
-
Reference
3GPP TS 27.007
[13][14]
Note
3.2.17 AT+CLCK Facility Lock
AT+CLCK Facility Lock
Test Command
AT+CLCK=?
Response
+CLCK: (list of supported <fac>s)