Data Sheet

Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 44 2015-08-03
The result codes, their numeric equivalents and brief descriptions of the use
of each are listed in the following table.
Parameter Saving
Mode
AT&W_SAVE
Max Response
Time
-
Reference
V.25ter
Note
ATV1 ATV0 Description
OK 0 Acknowledges execution of a Command
CONNECT 1 A connection has been established; the DCE is moving from
Command state to online data state
RING 2 The DCE has detected an incoming call signal from
network
NO CARRIER 3 The connection has been terminated or the attempt to
establish a connection failed
ERROR 4 Command not recognized, Command line maximum length
exceeded, parameter value invalid, or other problem with
processing the Command line
NO DIALTONE 6 No dial tone detected
BUSY 7 Engaged (busy) signal detected
NO ANSWER 8 "@" (Wait for Quiet Answer) dial modifier was used, but
remote ringing followed by five seconds of silence was not
detected before expiration of the connection timer (S7)
PROCEEDING 9 An AT command is being processed
CONNECT
<text>
Manufacturer-
specific
Same as CONNECT, but includes manufacturer-specific
text that may specify DTE speed, line speed, error control,
data compression, or other status
2.2.26 ATX Set CONNECT Result Code Format and Monitor Call Progress
ATX Set CONNECT Result Code Format and Monitor Call Progress
Response
This parameter setting determines whether or not the TA detected the
presence of dial tone and busy signal and whether or not TA transmits
particular result codes.
OK
ERROR
Execution
Command
ATX<value>
Parameters
<value> 0 CONNECT result code only returned, dial tone and busy