20 AT Commands Examples
20.1 Profile Commands
Demonstration Syntax Expect Result
The AT Command interpreter actively
responds to input.
AT OK
Display the product name and the
product release information.
ATI SIM800 R11.08
OK
Display product identification
information: the manufacturer, the
product name and the product revision
information.
AT+GSV SIMCOM_Ltd
SIMCOM_SIM800H
Revision:
1308B01SIM800H32
OK
Display current configuration, a list of
the current active profile parameters.
AT&V [A complete listing of the
active profile]
OK
Reporting of mobile equipment errors.
The default CME error reporting setting
is disabled. Switch to verbose mode
Displays a string explaining the error in
more details.
AT+CMEE= ?
AT+CMEE?
AT+CSCS=?
AT+CSCS="TEST"
AT+CMEE= 2
AT+CSCS="TEST"
+CMEE: (0-2)
OK
+CMEE: 1
OK
+CSCS:
("IRA","GSM","UCS2","HE
X","PCCP","PCDN","8859-
1")
OK
ERROR
OK
+CME ERROR: invalid
input value
Store the current configuration in
nonvolatile memory. When the board is
reset, the configuration changes from the
last session are loaded.
ATE0&W
AT
[Reset the board]
AT
OK
[No echo]
OK
[No echo]