Data Sheet
Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 35 2015-08-03
2.2.7 ATE Set Command Echo Mode
ATE Set Command Echo Mode
Response
This setting determines whether or not the TA echoes characters received
from TE during Command state.
OK
Execution
Command
ATE<value>
Parameters
<value> 0 Echo mode off
1 Echo mode on
Parameter Saving
Mode
AT&W_SAVE
Max Response
Time
-
Reference
V.25ter
Note
2.2.8 ATH Disconnect Existing Connection
ATH Disconnect Existing Connection
Execution
Command
ATH
Response
Disconnect existing call by local TE from Command line and terminate call
OK
Note: OK is issued after circuit 109(DCD) is turned off, if it was previously
on.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
20s
Reference
V.25ter
Note
2.2.9 ATI Display Product Identification Information
ATI Display Product Identification Information
Execution
Command
ATI
Response
TA issues product information text
Example:
SIM800 R11.08
OK