Data Sheet

Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 255 2015-08-03
Response
+CIPBEIPING: <mode>
OK
Read Command
AT+CIPBEIPING?
Parameters
See Write Command
Response
OK
or
ERROR
or
+CME ERROR: <err>
Write Command
AT+CIPBEIPING=
<
mode>
Parameters
<mode> 0 Disable the module to be PING.
1 Enable the module to be PING.
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference
Note
If the user want the module can be PING by other device, the user
must excute the AT+CIPBEIPING=1 before the module is PING.
Part of the projects supported by this AT command, please refer to
chapter 21 for details.