Data Sheet

Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 223 2015-08-03
0 IP INITIAL
1 IP START
2 IP CONFIG
3 IP GPRSACT
4 IP STATUS
5 TCP CONNECTING/UDP CONNECTING/
SERVER LISTENING
6 CONNECT OK
7 TCP CLOSING/UDP CLOSING
8 TCP CLOSED/UDP CLOSED
9 PDP DEACT
In Multi-IP state:
0 IP INITIAL
1 IP START
2 IP CONFIG
3 IP GPRSACT
4 IP STATUS
5 IP PROCESSING
9 PDP DEACT
Parameter Saving
Mode
NO_SAVE
Max Response
Time
When mode is multi-IP state, the max response time75 seconds.
When mode is single state, and the state is IP INITIAL, the max response
time is 160 seconds.
Reference
Note
This command allows establishment of a TCP/UDP connection only
when the state is IP INITIAL or IP STATUS when it is in single state.
In multi-IP state, the state is in IP STATUS only. So it is necessary to
process "AT+CIPSHUT" before user establishes a TCP/UDP
connection with this command when the state is not IP INITIAL or IP
STATUS.
When module is in multi-IP state, before this command is executed, it
is necessary to process "AT+CSTT, AT+CIICR, AT+CIFSR".
8.2.3 AT+CIPSEND Send Data Through TCP or UDP Connection
AT+CIPSEND Send Data Through TCP or UDP Connection
Test Command
AT+CIPSEND=?
Response
1) For single IP connection (+CIPMUX=0)
+CIPSEND: <length>
OK
2) For multi IP connection (+CIPMUX=1)
+CIPSEND: (0-5),<length>