Data Sheet

Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 209 2015-08-03
0 Detached
1 Attached
Other values are reserved and will result in an ERROR response to the
Write Command.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
10 seconds
Reference
Note
7.2.2 AT+CGDCONT Define PDP Context
AT+CGDCONT Define PDP Context
Response
+CGDCONT: (range of supported <cid>s),<PDP_type>,,,(list of
supported<d_comp>s),(list of supported<h_comp>s)
[<CR><LF>+CGDCONT:
(range of supported <cid>s), <PDP_type>,,,(list ofsupported
<d_comp>s),(list of supported <h_comp>s)[...]]
OK
Test Command
AT+CGDCONT
=?
Parameters
See Write Command
Response
+CGDCONT:
<cid>,<PDP_type>,<APN>,<PDP_addr>,<data_comp>,<head_comp>
[<CR><LF>+CGDCONT:
<cid>,<PDP_type>,<APN>,<PDP_addr>,<data_comp>,<head_comp>
[…]]
OK
Read Command
AT+CGDCONT
?
Parameters
See Write Command
Response
OK
ERROR
Write Command
AT+CGDCONT
=<cid>[,<PDP_ty
pe>[,APN>[,<PD
P_addr>[,<d_co
mp>[,<h_comp>]
]]]]
Parameters
<cid> (PDP Context Identifier) a numeric parameter which
specifies a particular PDP context definition. The parameter
is local to the TE-MT interface and is used in other PDP
context-related commands. The range of permitted values
(minimum value=1) is returned by the test form of the