Data Sheet

Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 198 2015-08-03
OK
Parameters
See Write Command
Response
OK
Write Command
AT+CNETSCA
N=<format>
Parameters
<format> 0 Hide lac and bsic information
1 Show lac and bsic information
Response
If format’s value is 0:
Operator:"<Network_Operator_name>",MCC:<MCC>,MNC:<MNC>
,Rxlev:<Rxlev>,Cellid:<CellID>,Arfcn:<Arfcn>[<CR><LF>Operator:
"<Network_Operator_name2>",MCC:<MCC2>,MNC:<MNC2>,Rxlev
:<Rxlev2>,Cellid:<CellID2>,Arfcn:<Arfcn2>[…]]
If format’s value is 1:
Operator:"<Network_Operator_name>",MCC:<MCC>,MNC:<MNC>
,Rxlev:<Rxlev>,Cellid:<CellID>,Arfcn:<Arfcn>,Lac:<Lac>,Bsic:<Bsic
>[<CR><LF>Operator:"<Network_Operator_name2>",MCC:<MCC2
>,MNC:<MNC2>,Rxlev:<Rxlev2>,Cellid:<CellID2>,Arfcn:<Arfcn2>,L
ac:<Lac2>,Bsic:<Bsic2>[…]]
OK
Execution
Command
AT+CNETSCA
N
Parameters
<Network_Operator_name> Long format alphanumeric of network
operator.
<MCC> Mobile country code.
<MNC> Mobile network code.
<Rxlev> Recieve level, in decimal format.
<CellID> Cell identifier, in hexadecimal format.
<Arfcn> Absolute radio frequency channel number, in decimal format.
<Lac> Location area code, in hexadecimal format.
<Bsic> Base station identity code, in hexadecimal format.
Parameter Saving
Mode
NO_SAVE
Max Response
Time
45s
Reference Note
6.2.68 AT+CMNRP Dual Serial Port Feature
AT+CMNRP Dual Serial Port Feature
Test Command Response