Data Sheet
Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 193 2015-08-03
6.2.61 AT+CANT Antenna Detecting
AT+CANT Antenna Detecting
Response
+CANT: (list of supported <mode>s),(list of supported
<UrcEnable>s),(list of supported <timer>s)
OK
+CME ERROR: <err>
Test Command
AT+CANT=?
Parameters
See Write Command
Response
+CANT: <mode>, <UrcEnable>, <timer>
OK
+CME ERROR: <err>
Read Command
AT+CANT?
Parameters
See Write Command
Response
OK
+CANT: <status>
Write Command
AT+CANT=<mo
de>,<UrcEnable
>,<timer>
Parameters
<mode> 0 Disable the antenna detecting function
1 Enable the antenna detecting function
<UrcEnable> 0 Disable reporting antenna state by URC
1 Enable reporting antenna state by URC
<timer> 0-3600 Reporting timer in units of seconds, range:
0-3600. Set timer to 0 will close detect, the
recommend value is 10.
<status> 0 Connected normally
1 Connected to GND
2 Connected to other power source
3 Not connected
Parameter Saving
Mode
AT&W_SAV E
Max Response
Time
-
Reference
Note
Part of the projects supported by this AT command, please refer to chapter