Data Sheet
Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 191 2015-08-03
<display>
0 Report jamming status via URC every 3000ms. (only
when <mode> is set to “1” or “3”)
1 Report jamming status via URC when jamming status
changed.(only when <mode> is set to “1” or “3”)
Parameter Saving
Mode
NO_SAVE
Max Response Time -
Reference
Note
When you query jamming detection status after enable jamming
detection mode, you will get the URC of the format below:
+SJDR:1,<mode>,<var>,<display>,<result>
<result>=0, means no jamming.
<result>=1, means jamming is detected.
<result>=2, means industrial interference is detected.
“+SJDR: INTERFERENCE DETECTED” indicates industrial
interference which signifies unintentional radio link disturbances by
strong industrial radio sources.
Jamming detection PIN is designed to indicate jamming by
outputting different level. When jamming is detected, the PIN will
output a high level, otherwise, it will output a low level.
Jamming detection PIN is different among SIM800 series project,
please refer to chapter 21 for details.
6.2.59 AT+CPCMCFG Set PCM Parameter
AT+CPCMCFG Set PCM Parameter
Response
+CPCMCFG: (0-1)
OK
Test Command
AT+CPCMCFG
=?
Parameters
See Write Command
Response
+CPCMCFG: <format>
OK
Read Command
AT+CPCMCFG
?
Parameters
See Write Command
Write Command
AT+CPCMCFG
=<format>
Response
OK
ERROR