Data Sheet

Smart Machine Smart Decision
SIM800 Series_AT Command Manual_V1.09 163 2015-08-03
<ts> Timeslot number
<maio> MAIO value
<hsn> HSN value
<rxq_sub> Receiving quality (sub), range is 0 - 7
<rxq_full> Receiving quality (full), range is 0 – 7
<ch_mod> Speech channel type, in string format
Parameter Saving
Mode
NO_SAVE
Max Response
Time
-
Reference Note
<lac> and <cellid> are in hex, <ch_mod> is string, and others are in
DEC.
If network supports frequency hopping, then <tch> is invalid, value is
0.
Under non-dedicated mode:
<tch>,<ts>,<maio>,<hsn>,<rxq_sub>,<rxq_full>,<ch_mod>
parameters are invalid, shown in "x".
Under dedicated mode, <c1> and<c2> in service cell are invalid, either
all neighbor cell parameters.
Parameter <rssi> value of "AT+CSQ" is half of <rxl>. The sum of
<dbm> and <rxl> is 113. That is to say, <rssi> = <rxl>/2 and
<dbm>=113-<rxl>.
6.2.22 AT+SCLASS0 Store Class 0 SMS to SIM When Received Class 0 SMS
AT+SCLASS0 Store Class 0 SMS to SIM When Module Received Class 0 SMS
Response
+SCLASS0: (0, 1)
OK
Test Command
AT+SCLASS0=?
Parameters
See Write Command
Response
+SCLASS0: <mode>
OK
Read Command
AT+SCLASS0?
Parameters
See Write Command
Response
OK
ERROR
Write Command
AT+SCLASS0=<
mode>
Parameters