Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  41  2015-08-03 
Time 
Reference 
V.25ter 
Note 
Default 8 = Backspace. 
2.2.20 ATS6    Pause Before Blind Dialling 
ATS6 Pause Before Blind Dialling 
Read Command 
ATS6? 
Response 
<n> 
OK 
Response 
OK 
ERROR 
Write Command 
ATS6=<n> 
Parameters 
<n> 0..999 Time 
Parameter Saving 
Mode 
AT&W_SAVE 
Max Response 
Time 
- 
Reference 
V.25ter 
Note 
No effect in GSM 
2.2.21 ATS7 Set Number of Seconds to Wait for Connection Completion 
ATS7 Set Number of Seconds to Wait for Connection Completion 
Response 
<n> 
OK 
Read Command 
ATS7? 
Parameters 
See Write Command 
Response 
This parameter setting determines the amount of time to wait for the 
connection completion in case of answering or originating a call. 
OK 
ERROR 
Write Command 
ATS7=<n> 
Parameters 
<n> 1-60-255 Number of seconds to wait for connection completion 
Parameter Saving 
Mode 
AT&W_SAVE 