Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  36  2015-08-03 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
V.25ter 
Note 
2.2.10 ATL    Set Monitor speaker loudness 
ATL Set Monitor speaker loudness 
Response 
OK 
Execution 
Command 
ATL<value> 
Parameters 
<value> 0..9 Volume 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
V.25ter 
Note 
No effect in GSM 
2.2.11 ATM Set Monitor Speaker Mode 
ATM Set Monitor Speaker Mode 
Response 
OK 
Execution 
Command 
ATM<value> 
Parameters 
<value> 0..9 Mode 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
V.25ter 
Note 
No effect in GSM 
2.2.12 +++ Switch from Data Mode or PPP Online Mode to Command Mode 
+++ Switch from Data Mode or PPP Online Mode to Command Mode 
Execution 
Command 
+++ 
Response 
The +++ character sequence causes the TA to cancel the data flow over the 
AT interface and switch to Command mode. This allows you to enter AT 
Command while maintaining the data connection to the remote server. 
OK 