Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  355  2015-08-03 
20 AT Commands Examples 
20.1 Profile Commands 
Demonstration  Syntax  Expect Result 
The AT Command interpreter actively 
responds to input. 
AT  OK 
Display the product name and the 
product release information. 
ATI  SIM800 R11.08 
OK 
Display product identification 
information: the manufacturer, the 
product name and the product revision 
information. 
AT+GSV  SIMCOM_Ltd 
SIMCOM_SIM800H 
Revision: 
1308B01SIM800H32 
OK 
Display current configuration, a list of 
the current active profile parameters. 
AT&V  [A complete listing of the 
active profile] 
OK 
Reporting of mobile equipment errors. 
The default CME error reporting setting 
is disabled. Switch to verbose mode 
Displays a string explaining the error in 
more details. 
AT+CMEE= ? 
AT+CMEE? 
AT+CSCS=? 
AT+CSCS="TEST" 
AT+CMEE= 2 
AT+CSCS="TEST" 
+CMEE: (0-2) 
OK 
+CMEE: 1 
OK 
+CSCS: 
("IRA","GSM","UCS2","HE
X","PCCP","PCDN","8859-
1") 
OK 
ERROR 
OK 
+CME ERROR: invalid 
input value 
Store the current configuration in 
nonvolatile memory. When the board is 
reset, the configuration changes from the 
last session are loaded. 
ATE0&W 
AT 
[Reset the board] 
AT 
OK 
[No echo] 
OK 
[No echo] 
OK 