SIM800 Series_AT Command Manual_V1.09  262  2015-08-03 
If<byte_size> is bigger than the data size received, module will only return 
actual data size. 
If error is related to ME functionality: 
+CME ERROR: <err> 
Parameters 
<data>   Data from HTTP server or user input. 
<start_address> The starting point for data output. 
0-319488 (bytes) 
<byte_size> The length for data output. 
1-319488 (bytes) 
<data_len> The actual length for data output. 
Execution 
Command 
AT+HTTPREA
D 
Response 
+HTTPREAD:<date_len> 
<data> 
OK 
Read all data when AT+HTTPACTION=0 or AT+HTTPDATA is executed. 
If error is related to ME functionality: 
+CME ERROR: <err> 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
Note 
11.2.7 AT+HTTPSCONT Save HTTP Application Context 
AT+HTTPSCONT Save HTTP Application Context 
Read Command 
AT+HTTPSCON
T? 
Response 
TA returns HTTP Application Context, which consists of the following 
AT Command parameters. 
+HTTPSCONT:<mode> 
CID:<value> 
URL: <value> 
UA: <value> 
PROIP: <value> 
PROPORT: <value> 
REDIR: <value> 
BREAK: <value> 