Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  241  2015-08-03 
OK 
ERROR 
AT+CIPCCFG=
<NmRetry>,<Wa
itTm>,<SendSz>,
<esc>[,<Rxmode
>,<RxSize>,<Rxt
imer>] 
Parameters 
<NmRetry> Number of retries to be made for an IP packet. 
<WaitTm> Number of 100ms intervals to wait for serial input before 
sending the packet. 
<SendSz> Size in bytes of data block to be received from serial port 
before sending. 
<esc>  Whether turn on the escape sequence, default is TRUE. 
 0 Turn off the escape sequence 
  1 Turn on the escape sequence 
<Rxmode>      Whether to set time interval during output data from serial 
port. 
0 output data to serial port without interval 
1 output data to serial port within <Rxtimer> interval. 
<RxSize> Output data length for each time, default value is 1460. 
<Rxtimer>  Time interval (ms) to wait for serial port to output data 
again. Default value: 50ms 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
- 
Reference 
Note 
This command will be effective only in single connection mode 
(+CIPMUX=0) 
8.2.24 AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data 
AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data 
Response 
+CIPSHOWTP: (list of supported <mode>s) 
OK 
Test Command 
AT+CIPSHOWTP
=? 
Parameters 
See Write Command 
Response 
+CIPSHOWTP: <mode> 
OK 
Read Command 
AT+CIPSHOWTP
? 
Parameters 
See Write Command 
Write Command 
AT+CIPSHOWTP
Response 
OK 