Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  213  2015-08-03 
<mean> A numeric parameter which specifies the mean throughput 
class 
0   QOS mean throughput class subscribed value 
1..18 QOS mean throughput class 
31 
QOS mean throughput class best effort
Parameter Saving 
Mode 
AUTO_SAVE 
Max Response 
Time 
- 
Reference 
Note 
7.2.5 AT+CGACT PDP Context Activate or Deactivate 
AT+CGACT PDP Context Activate or Deactivate 
Response 
+CGACT: (list of supported <state>s) 
OK 
Test Command 
AT+CGACT=? 
Parameters 
See Write Command 
Response 
+CGACT: <cid>,<state>[<CR><LF>+CGACT:<cid>,<state>…] 
OK 
Read Command 
AT+CGACT? 
Parameters 
See Write Command 
Response 
OK 
If error is related to ME functionality: 
+CME ERROR: <err> 
Write Command 
AT+CGACT=<st
ate>[,<cid>] 
Parameters 
<state> Indicates the state of PDP context activation 
 0 Deactivated 
 1 Activated 
 Other values are reserved and will result in an ERROR 
response to the Write Command. 
<cid> A numeric parameter which specifies a particular PDP context 
definition (see +CGDCONT Command). If the <cid> is 
omitted, it only affects the first cid. 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 150 seconds 