Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  209  2015-08-03 
  0  Detached 
  1 Attached 
Other values are reserved and will result in an ERROR response to the 
Write Command. 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
10 seconds 
Reference 
Note 
7.2.2 AT+CGDCONT Define PDP Context 
AT+CGDCONT Define PDP Context 
Response 
+CGDCONT: (range of supported <cid>s),<PDP_type>,,,(list of 
supported<d_comp>s),(list of supported<h_comp>s) 
[<CR><LF>+CGDCONT: 
(range of supported <cid>s), <PDP_type>,,,(list ofsupported 
<d_comp>s),(list of supported <h_comp>s)[...]] 
OK 
Test Command 
AT+CGDCONT
=? 
Parameters 
See Write Command 
Response 
+CGDCONT: 
<cid>,<PDP_type>,<APN>,<PDP_addr>,<data_comp>,<head_comp> 
[<CR><LF>+CGDCONT: 
<cid>,<PDP_type>,<APN>,<PDP_addr>,<data_comp>,<head_comp> 
[…]] 
OK 
Read Command 
AT+CGDCONT
? 
Parameters 
See Write Command 
Response 
OK 
ERROR 
Write Command 
AT+CGDCONT
=<cid>[,<PDP_ty
pe>[,APN>[,<PD
P_addr>[,<d_co
mp>[,<h_comp>]
]]]] 
Parameters 
<cid> (PDP Context Identifier) a numeric parameter which 
specifies a particular PDP context definition. The parameter 
is local to the TE-MT interface and is used in other PDP 
context-related commands. The range of permitted values 
(minimum value=1) is returned by the test form of the 