<display> 
0 Report jamming status via URC every 3000ms. (only 
when <mode> is set to “1” or “3”) 
1 Report jamming status via URC when jamming status 
changed.(only when <mode> is set to “1” or “3”) 
Parameter Saving 
Mode 
NO_SAVE 
Max Response Time - 
Reference 
Note 
  When you query jamming detection status after enable jamming 
detection mode, you will get the URC of the format below: 
+SJDR:1,<mode>,<var>,<display>,<result> 
<result>=0, means no jamming. 
<result>=1, means jamming is detected. 
<result>=2, means industrial interference is detected. 
  “+SJDR: INTERFERENCE DETECTED” indicates industrial 
interference which signifies unintentional radio link disturbances by 
strong industrial radio sources. 
  Jamming detection PIN is designed to indicate jamming by 
outputting different level. When jamming is detected, the PIN will 
output a high level, otherwise, it will output a low level. 
  Jamming detection PIN is different among SIM800 series project, 
please refer to chapter 21 for details. 
6.2.59 AT+CPCMCFG Set PCM Parameter 
AT+CPCMCFG Set PCM Parameter 
Response 
+CPCMCFG: (0-1) 
OK 
Test Command 
AT+CPCMCFG
=? 
Parameters 
See Write Command 
Response 
+CPCMCFG: <format> 
OK 
Read Command 
AT+CPCMCFG
? 
Parameters 
See Write Command 
Write Command 
AT+CPCMCFG
=<format> 
Response 
OK 
ERROR 