Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  147  2015-08-03 
OK 
Parameters 
See Write Command 
Response 
+CMIC: (<channel0>,<gainlevel0>),…,(<channeln>,<gainleveln>) 
OK 
Read Command 
AT+CMIC? 
Parameters 
See Write Command 
Response 
OK 
ERROR 
Write Command 
AT+CMIC=<cha
nnel>,<gainlevel
> 
Parameters 
<channel> 0 Main audio channel 
1  Aux audio channel 
2  Main audio channel hand free mode 
3  Aux audio channel hand free mode 
<gainlevel> Int: 0 – 15 
0 0dB 
1 +1.5dB 
2 +3.0 dB 
3 +4.5 dB 
4 +6.0 dB 
5 +7.5 dB 
6 +9.0 dB 
7 +10.5 dB 
8 +12.0 dB 
9 +13.5 dB 
10 +15.0 dB 
11 +16.5 dB 
12 +18.0 dB 
13 +19.5 dB 
14 +21.0 dB 
15 +22.5 dB 
Parameter Saving 
Mode 
AUTO_SAVE 
Max Response 
Time 
- 
Reference Note 
  <gainleveln> value is related to <channel> specific. 
  The default gain level of main audio channel is 10. 
  Scope of parameter <channel> is different among SIM800 series 