Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  123  2015-08-03 
Max Response 
Time 
5s 
Reference 
3GPP TS 27.005 
Note 
4.2.7 AT+CMSS Send SMS Message from Storage 
AT+CMSS  Send SMS Message from Storage 
Test Command 
AT+CMSS=? 
Response 
OK 
Response 
TA sends message with location value <index> from message storage 
<mem2> to the network (SMS-SUBMIT). If new recipient address <da> is 
given, it shall be used instead of the one stored with the message. Reference 
value <mr> is returned to the TE on successful message delivery. Values can 
be used to identify message upon unsolicited delivery status report result 
code. 
1) If text mode(+CMGF=1) and sending successful: 
+CMSS: <mr> 
OK 
2) If PDU mode(+CMGF=0) and sending successful: 
+CMSS: <mr> 
OK 
3)If error is related to ME functionality: 
+CMS ERROR: <err> 
Write Command 
AT+CMSS=<ind
ex>[,<da>,<toda
>] 
Parameters 
<index>  Integer type; value in the range of location numbers supported 
by the associated memory 
<da>  GSM 03.40 TP-Destination-Address Address-Value field in 
string format(string should be included in quotation marks); BCD numbers 
(or GSM default alphabet characters) are converted to characters of the 
currently selected TE character set (specified by +CSCS in 3GPP TS 
27.007); type of address given by <toda> 
<toda>  GSM 04.11 TP-Destination-Address Type-of-Address octet 
in integer format (when first character of <da> is + (IRA 43) default is 145, 
otherwise default is 129) 
<mr>   GSM 03.40 TP-Message-Reference in integer format 
Parameter Saving 
Mode 
NO_SAVE 
Max Response 
Time 
60s 
Reference Note 