Data Sheet
     Smart Machine Smart Decision 
SIM800 Series_AT Command Manual_V1.09  122  2015-08-03 
27.007); type of address given by <toda> 
<tooa>  GSM 04.11 TP-Originating-Address Type-of-Address octet 
in integer format (default refer <toda>) 
<toda>  GSM 04.11 TP-Destination-Address Type-of-Address octet in 
integer format (when first character of <da> is + (IRA 43) default is 145, 
otherwise default is 129) 
129 Unknown type(IDSN format number) 
161 National number type(IDSN format) 
145 International number type(ISDN format) 
177 Network specific number(ISDN format) 
<length>  Integer type value (not exceed 160 bytes) indicating in the 
text mode (+CMGF=1) the length of the message body <data> (or 
<cdata>) in characters; 
or in PDU mode (+CMGF=0), the length of the actual TP 
data unit in octets (i.e. the RP layer SMSC address octets are 
not counted in the length) 
<stat> in the text mode (+CMGF=1): 
 "STO UNSENT"  Stored unsent messages 
  "STO SENT"   Stored sent messages 
 in PDU mode (+CMGF=0): 
 0 Received unread messages 
  1 Received read messages 
  2 Stored unsent messages 
  3 Stored sent messages 
<pdu>  In the case of SMS: GSM 04.11 SC address followed by 
GSM 03.40 TPDU in hexadecimal format: ME/TA converts each octet of 
TP data unit into two IRA character long hexadecimal number (e.g. octet 
with integer value 42 is presented to TE as two characters 2A (IRA 50 and 
65)). In the case of CBS: GSM 03.41 TPDU in hexadecimal format. 
<index>  Index of message in selected storage <mem2> 
Execution 
Command 
AT+CMGW 
Response 
TA transmits SMS message (either SMS-DELIVER or SMS-SUBMIT) 
from TE to memory storage <mem2>. Memory location <index> of the 
stored message is returned. By default message status will be set to 'stored 
unsent', but parameter <stat> allows also other status values to be given. 
If writing is successful: 
+CMGW: <index> 
OK 
If error is related to ME functionality: 
+CMS ERROR: <err> 
Parameter Saving 
Mode 
NO_SAVE 