Data Sheet
CC1101
SWRS061B Page 49 of 93
315 MHz 433 MHz 868 MHz 915 MHz
Output
Power
[dBm]
Setting
Current
Consumption,
Typ. [mA]
Setting
Current
Consumption,
Typ. [mA]
Setting
Current
Consumption,
Typ. [mA]
Setting
Current
Consumption,
Typ. [mA]
-30 0x12 10.9 0x12 11.9 0x03 12.1 0x03 12.0
-20 0x0D 11.4 0x0E 12.4 0x0F 12.7 0x0E 12.6
-15 0x1C 12.0 0x1D 13.1 0x1E 13.4 0x1E 13.4
-10 0x34 13.5 0x34 14.4 0x27 15.0 0x27 14.9
-5 0x69 12.8 0x68 13.8 0x67 14.4 0x39 17.7
0 0x51 15.0 0x60 15.9 0x50 16.9 0x8E 16.7
5 0x85 18.3 0x84 19.4 0x81 21.0 0xCD 24.3
7 0xCB 22.1 0xC8 24.2 0xCB 26.8 0xC7 26.9
10 0xC2 26.9 0xC0 29.1 0xC2 32.4 0xC0 31.8
Table 30: Optimum PATABLE Settings for Various Output Power Levels and Frequency Bands
315 MHz 433 MHz 868 MHz 915 MHz
Default
Power
Setting
Output
Power
[dBm]
Current
Consumption,
Typ. [mA]
Output
Power
[dBm]
Current
Consumption,
Typ. [mA]
Output
Power
[dBm]
Current
Consumption,
Typ. [mA]
Output
Power
[dBm]
Current
Consumption,
Typ. [mA]
0xC6 8.5 24.4 7.8 25.2 8.5 29.5 7.2 27.4
Table 31: Output Power and Current Consumption for Default PATABLE Setting
25 Shaping and PA Ramping
With ASK modulation, up to eight power
settings are used for shaping. The modulator
contains a counter that counts up when
transmitting a one and down when transmitting
a zero. The counter counts at a rate equal to 8
times the symbol rate. The counter saturates
at FREND0.PA_POWER and 0 respectively.
This counter value is used as an index for a
lookup in the power table. Thus, in order to
utilize the whole table, FREND0.PA_POWER
should be 7 when ASK is active. The shaping
of the ASK signal is dependent on the
configuration of the PATABLE.
Figure 23 shows some examples of ASK
shaping.