Specifications

47
VFO A Knob Friction Adjustment
The VFO A knobs spin rate can be adjusted by
movingthe knob in or out slightly. The rubber
finger grip on the VFO A knob covers the knobs
set screw, so it must be removed first.
In the following procedure, use only your
fingernails; a tool may scratch the knob.
Using your fingernails at the point identified below,
pull the finger grip forward slightly. Rotate the
knob and repeat until the grip can be pulled off.
Use the supplied 5/64" (2 mm) Allen wrench to
loosen the set screw.
Between the knob andfront panel are two felt
washers which, when compressed, reduce the spin
rate. Movethe knob in or out in small increments
until the desired rate isobtained. (Re-tighten the set
screw each time so you can spin the knob.) Then
and replace the finger grip.
VFO B Knob Friction Adjustment
Use the supplied 5/64" (2 mm) Allen wrench to
loosen the VFO B knobs set screw.
Between the knob andfront panel is a felt washer
which, when compressed, reduces the spin rate.
Movethe knob in or out in small increments until
the desired rate is obtained, re-tighteningthe set
screw each time.
Real Time Clock Battery Replacement
K3 components or modules can be easily be
damaged by ESD (electrostatic discharge). To
avoid this, put on a grounded wrist strap (with 1
megohm series resistor) or touch a grounded
surface before touching anything inside the
enclosure. An anti-static work mat is strongly
recommended.
The battery for the real time clock/calendar is
located onthe left side ofthe RF board. To access
it, turn power off, then remove thetop cover as
described in Appendix A.
Removethe sub receiver module (KRX3) if present.
Removethe old battery.
If a KRX3 module (sub receiver) is installed,
the battery will be protected by a plastic sleeve,
which prevents shorting to the KRX3 module. Be
sure to save this sleeve and replace it when the
new battery is installed.
Replace the battery with the same type of 3-V
lithium coin cell (CR2032, BR2032, equivalent).
The (+) terminal is clearly marked on the battery; it
must be oriented as indicated by the (+) symbol on
the RF board. Re-install the KRX3 module (if
applicable) andthe top cover.
To set the time, date, and date format, refer to the
following CONFIG menu entries: TIME, DATE,
and DATE MD.