Owner`s manual

9
Remove the stiffener as shown in Figure 4. It will be held in place by a flat head screw through each side
panel. If the KPA3 100 watt amplifier option is installed, two screws securing it to the KPA3 shield. Some older
K3s may use nuts and lock washers on the screws securing the stiffener to the KPA3 shield instead of PEM nuts.
Figure 4. Removing the Chassis Stiffener.
Remove the three screws that hold the K144XV module to the side panel (see Figure 5). You do not need to
remove the module but only free it so it can be moved back away from the main synthesizer board far enough to
gain access to it.
Figure 5. Removing the K144XV Module Mounting Screws.
You can either unplug the coaxial cables or push the module aside to reach the mounting screw for the main
synthesizer board. To remove the cables, first remove the five screws securing the top cover and lift it off so you
can pull on the metal grip of each connector (see Figure 6). Do not pull on the coaxial cable; you might pull it
out of the TMP connector. If you remove it completely, a diagram is provided on page 14showing all of the
required cable connections to reinstall it.