Specifications

SIM900 AT Command Manual
SIM900_AT Command Manual_V1.03 86 12/24/2010
OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameters
<numericn> string type (string should be included in quotation marks):
operator in numeric format (see +COPS)
<alphan> string type (string should be included in quotation marks):
operator in long alphanumeric format (see +COPS)
Reference
GSM 07.07 [13]
Note
3.2.46 AT+CFUN Set Phone Functionality
AT+CFUN Set Phone Functionality
Response
+CFUN: (list of supported <fun>s),(list of supported <rst>s)
OK
If error is related to ME functionality:
+CME ERROR: <err>
Test Command
AT+CFUN=?
Parameters
See Write Command
Response
+CFUN: <fun>
OK
If error is related to ME functionality:
+CME ERROR: <err>
Read Command
AT+CFUN?
Parameters
See Write Command
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Write Command
AT+CFUN=<fun
>,[<rst>]
Parameters
<fun> 0 minimum functionality
1 full functionality (Default)
4 disable phone both transmit and receive RF circuits
<rst> 0 Do not reset the MT before setting it to <fun> power
level
1
Reset the MT before setting it to <fun> power level