Specifications

SIM900 AT Command Manual
SIM900_AT Command Manual_V1.03 34 12/24/2010
2.2.29 AT&D Set DTR Function Mode
AT&D Set DTR Function Mode
Response
This parameter determines how the TA responds when circuit 108/2 (DTR)
is changed from the ON to the OFF condition during data mode.
OK
ERROR
Execution
Command
AT&D[<value>]
Parameter
<value> 0 TA ignores status on DTR.
1 ON->OFF on DTR: Change to Command mode with
remaining the connected call.
2 ON->OFF on DTR: Disconnect call, change to Command
mode. During state DTR = OFF is auto-answer off.
Reference
V.25ter
Note
2.2.30 AT&F Factory Defined Configuration
AT&F Factory Defined Configuration
Response
TA sets all current parameters to the manufacturer defined profile.
OK
Execution
Command
AT&F[<value>]
Parameter
<value> 0 Set all TA parameters to manufacturer defaults.
Reference
V.25ter
Note
Parameter impacted by &F command:
Command Parameter name Default value
ATE <echo> 0x01
ATQ <result> 0x00
ATV <format> 0x01
ATX <result> 0x04
AT+IFC <TA_by_TE> 0x00
AT+IFC <TE_by_TA> 0x00
ATS0 <num> 0x00
ATS3 <char> 0x0D
ATS4 <char> 0x0A
ATS5 <char> 0x08