User manual
4
1. General Information
1.1 Function
ESIM251 is a microcontroller based device used to inform users about the alarm in automatic or security systems and control one
electric appliance -relay.
1.2 Operation Description
Description of factory default settings.
GSM control system ESIM251 operates over GSM network. It works 24/7, i. e. it always reacts to the incoming signal.
When the alarm siren, motion sensor, re alarm sensor, door sensor, any other sensor or PGM output is triggered, ESIM51 system sends
anSMSmessageandcallstothepresetnumbers.SMSmessagewiththenameofthetriggeredzone(input)willcontinuetobesentuntil
successful delivery to one of the users or until it is delivered to all users. The system continues to call until one of the ve users answers
the phone, rejects the call or until the call is ended by the mobile service provider. If the user answers the call, the system activates the
microphone for listening on what is happening in the secured premises. When using audio feature in case of zone trigger or restore event
the user will be able to listen to particular sound record uploaded to the ESIM251 device memory. After the end of the sound record the
system activates the microphone for listening on what is happening in the secured premises. After „hanging the phone“ or after the end
ofthecall(duration-1min.)thesystemwillreturntotheprevioussecuritystate.Please,referto“ELDES Conguration Tool“ software
„Help“ section for more details on audio feature.
ESIM251cancontrol1electronicappliance(arelay)sendingapasswordandaspecialcommandfromaGSMphoneofanyusers.
This feature allows to turn on the heating, lighting, lift the gates, blinds etc.
The system will ignore incoming requests from unknown telephone number or SMS message with wrong password.
List of other congurable system possibilities.
Input types
Normally open NO Operation only when the signal is transmitted.
Normally closed NC Operation only when the signal is switched.
Ways of activating an
event
Event when the input is
activated(Alarm)
SMS is delivered when the signal is transmitted to the input.
Event when the input is restored
(Restore)
SMS is delivered when the previously transmitted signal in the input
disappears.
Impulse counting
SMS is delivered if the number of te preset number of impulses in the
inputisexceeded.Maxvalueis4294967295impulses.
Ways of transmitting an
event
SMS
Only SMS or various call combinations can be chosen. It is also possible to
use only calls. Any of the users can be assigned only SMS or only calls or
call combinations. Besides, any of the users can be assigned a particular
input(zone)ortheircombination.E.g.apossibilitytocongurethe
system so that when input Z1 is activated SMS are sent only to users NR1
and NR5, and when Z2 is activated SMS is sent to all users and the call
would be for NR4 and so on. When the functions SMSALL and CALLSALL
are set SMS messages are sent to all users and the call would be delivered
regardless of the fact whether the call was answered, rejected etc.
Calls
Ways of controlling
output(relay)
Turning on/o by SMS
The relay can be turned on/o by sending the command by SMS
message. You can turn on/o:
1. for a permanent status
2. for a set period
3. for a set hour
4. repeating turning on/o.
Turning on/o by a call
The relay can be turned on/o by calling. You can turn on/o:
1. for a permanent status
2. for a set period
3.toggle(relaystatuschangesaftereachcall)
Automatic turning on at the
preset hour
The relay can be turned on for a set period at a set hour.
E. g. the relay is turned on at 18:00 and it is on for 5 hours. After 5 hours it
turns on automatically notifying the user about that.
Event register Event register function
When the computer is connected it is possible to see activations, network
strength etc.