User manual

18
E. g. 2.
TheuserwantstoconnectESIM251systemtotheprogrammableoutputs(PGM)ofanexistingalarmsystem.Houseterritoryis
entered through electrically controlled gates. There are 5 users in total. NO1 is the housekeeper, NO2 is a neighbour, NO3-NO5
are family members.
As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the rst successful
deliveryoftheSMSmessage,itisnecessarytoenablemandatorySMSmessagedelivery(seemoreinchapter3.7)andtoremove
the users who should not receive alarm messages. Besides, as per factory default settings, calling feature in the case of alarm is also
enabled for all users therefore call function must be disabled for users NO2-NO5 and left enabled for NO1 only.
a)Firstofallsecuritycentralunitmustbeprogrammedinthewaysothatwhensecuritysensorsaretriggeredthesignalmust
be transmitted to security central unit output PGM.
b)PGMisconnectedtoESIM251inputZ1
c)The following two conguration SMS messages must be sent to ESIM251 system:
where SMSALL enables mandatory SMS message delivery for all users.
Where SC345 means that alar SMS message sending is disabled for users NO3, NO4 and NO5 after Z1 zone is triggered.
CC2345 means that alarm calls are disabled for all users exept NO1 after Z1 zone is triggered.
Task NO1:
Conguringthesystemsothathousealarmactivationisreportedtothehousekeeper(NO1)bySMSmessageandacallaswellas
totheneighbour(NO2)butbySMSmessageonly.
XXXX_SMSALL:ON
XXXX_SMSEXTRA:Z1:SC345,CC2345
Housekeeper
NO1
Neighbour
NO2
Family members:
NO3 NO4 NO5
Alarm system
ESIM151
Alarm
SMS
Alarm
SMS/Calls
PIR PIR
PIRPIR
PGM
GATES
FOR ADVANCED USERS
All these features can be congured using program “ELDES Conguration Tool“