User manual

USER MANUAL ELDES ESIM251 V1.0 11
Disabling Zone
Any zone can be disabled by sending the following SMS message:
E. g. XXXX_Z2:ON; or XXXX_WINDOWS:ON; or XXXX_Z2:OFF; or XXXX_WINDOWS:OFF;
3.3 Info on Status SMS
The system ESIM251 can any time be inquired about signal strength and the status of zones active at the time when SMS message is
sent. At the same time system test is performed. If the answer to the request has been received, it means the system nely operates.
It is also useful for those using prepayment service – you can check if the credit in the account is sucient for sending an SMS
message. Send the following SMS message:
The reply SMS will have following info: e. g. 2008.08.07 11:15
Signal strength satisfactory. Z1:OK/ALARM Z2:OK/ALARM Z3:OK/ALARM Z4:OK/ALARM Z5:OK/ALARM
where OK means that the alarm in zone did not go o. ALARM – if it went o.
By default, this status SMS message will be sent daily at 11:00 in the morning. These parameters can
be congured by sending the following SMS message:
PP – message period in days, valid values [00-10].
VV - time when message is sent, valid values [00-23].
E. g. XXXX_INFO:01.10 means that status message will be sent every 1 day at 10:00.
If PP value is 0, and VV in the range of [1-23], then periodic status messages will be sent multiple times
per day, with period being specied as VV time.
E. g. XXXX_INFO:0.2 means that status message will be sent every 2 hours.
To disable periodic status messages send the following SMS message:
The status messages will not be sent until enabling or restoring default parameters or receiving previously described XXXX_
INFO:PP.VV SMS message.
3.4 Blocking Unknown Numbers
By default ESIM251 system can be controlled from any of the pre-programmed numbers NR1-NR5. However, the user can access
the system and control parameters and outputs from any number as long as password is known.
To enable this feature send the following SMS message:
To disable this feature send the following SMS message:
XXXX_Z1:OFF;Z2:OFF;Z3:OFF;Z4:OFF;Z5:OFF;
XXXX_INFO:PP.VV
XXXX_INFO:00.00
XXXX_STR:ON
XXXX_STR:OFF
XXXX_INFO
ESIM 251
XXXX_
WINDOWS:
OFF;
ESIM 251
XXXX_
INFO:01.
10
ESIM 251
XXXX_
INFO:0.2