ESIM022 GSM AUTO DIALLER
User Manual v1.2 SAFETY INSTRUCTIONS Please read and follow these safety guidelines to safeguard yourself and others: • GSM auto dialler ESIM022 (later referred to as “the system” or “the device”) contains a builtin radio transceiver operating in GSM 900/1800 MHz bands. • DO NOT use the system where it can cause potential danger and interfere with other devices – such as medical devices. • DO NOT use the system in hazardous environment.
To switch the system off, unplug the external electric power supply, disconnect the back-up battery or any other linked device that the system is powered from. A blown fuse cannot be replaced by the user. The replacement fuse has to be of the kind indicated by the manufacturer (Fuse F1 model – miniSMDC 0,5A). If you use a computer for the device configuration, it must earthed.
Contents 1. GENERAL INFORMATION............................................................................................... 7 2. TECHNICAL SPECIFICATIONS......................................................................................... 8 2.2. Wiring Diagrams........................................................................................................................... 10 3. INSTALLATION......................................................................................................
Copyright © “ELDES UAB”, 2014. All rights reserved It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a warning. Hereby, “ELDES UAB” declares that the GSM auto dialler ESIM022 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Limited Liability The buyer agrees that the system will reduce the risk of fire, theft, burglary or other danger but that it does not guarantee against the occurrence of such events. “ELDES UAB” will not take any responsibility for the loss of personal effects, property or revenue whilst using the system. The liability of “ELDES UAB” is limited to the value of the system purchased.
1. GENERAL INFORMATION ESIM022 is a micro-controller based device intended to receive alarm/restore events by SMS text message or phone call and control an electrical appliance via the GSM network. Examples of using the system: • Notification of system events, such as arming/disarming, alarm/restore from non-GSM alarm system. • Non-GSM alarm system arming/disarming by SMS text message. • Any electrical appliance control: lighting, watering, heating etc.
2. TECHNICAL SPECIFICATIONS 2.1. Electrical & Mechanical Characteristics Supply voltage......................................................12-15 V 300 mA max Average current used in idle state .................... 16 mA Supported back-up battery (optional).............8.4V 250mAh rechargeable Ni-Mh 6HR61 (IEC)/7.2H5 (ANSI/NEDA) GSM modem frequency.......................................900/1800 MHz Number of outputs..............................................1 OUT Output circuit..........................
Main Unit Functionality ANT GSM antenna FW Pins for firmware update TAMPER Tamper switch GSM MODEM GSM network 900/1800 MHz modem RESET Button for restoring default settings SIM CARD SIM card slot / holder LED Light-emitting diode indicating system status USB Mini USB port MIC Microphone connector -/+ Backup battery slots F1 0.5A fuse LED indication Description OFF No power supply Flashing every 30 ms SIM card is not present / PIN code enabled Flashing every 0,5 sec.
2.2. Wiring Diagrams General wiring Temperature sensor wiring 3 ESIM022 Z1 COM Z2 DC COM C1 4 ESIM022 Z1 COM Z2 DC COM C1 DATA +4V GND PGM2 PGM1 DS18S20 temperature sensor GND DATA +4V +12V Alarm system or other appliance Output wiring 5 5 ESIM022 Z1 COM Z2 DC COM C1 red ++ yellow Z1 COM Z2 DC COM C1 black ESIM022 Vinson DS18B20 digital thermometer wiring Electrical appliance +12 V Alarm system or other appliance 10 EN Vinson DS18B20 digital thermometer ESIM022 User manual v1.
3. INSTALLATION • The system should be installed indoors, in stationary environment ONLY. • For the connection of input/output terminals, use 0.50mm2 (0.02in2) thread unshielded cable of up to 100m (328.08ft) length. 1. Wire up the system in accordance with the wiring diagrams (see 2.3 Wiring Diagrams for more details). 2. When placing the system, follow the recommendations: 6 Never install in the following locations: • inside the metal cabinet • closer than 20cm (7.
5. Once the PIN code is disabled, insert the SIM card into the SIM card slot / holder of ESIM022 system. 11 12 OPEN 10 OPEN Pull down 14 OPEN 13 6. If you have obtained a back-up battery with your system, insert it into the battery slots. Take care when connecting positive and negative battery terminals. 12 15 16 17 18 EN ESIM022 User manual v1.
7. Close the enclosure of ESIM022. 9 8. Power up the system and wait until the LED indicator lights up indicating system status. Wait until the LED indicator starts flashing every 1 second indicating successful connection to GSM network and system operation (see 2.2. Main Unit, LED Indicator & Connector Functionality for more details). 9. Set the phone number for User 1. 10. Set system date and time. 11. Once the system is fully configured, it is ready for use.
4. GENERAL OPERATION DESCRIPTION GSM auto dialler ESIM022 uses the GSM network for event transmission by SMS text message. When one of the two available listed numbers dials the system, it answers the call and the user can listen for up to 60 seconds to what is going on in the premises. This function operates only when a microphone is connected. The system will ignore SMS requests and phone calls coming from unknown phone numbers.
6. USER PHONE NUMBERS The system supports up to 2 user phone numbers identified as User 1 through 2. When the phone number is set, the user will be able to configure the system by SMS text messages as well as to receive the alarm phone calls and alarm/restore SMS text messages from the system (see 10. ALARM/RESTORE NOTIFICATIONS). The system ignores any incoming calls and SMS text messages from a non-listed phone number. To set User 1 phone number is mandatory, while User 2 is optional.
Delete user phone number SMS Config Tool SMS text message content: NR2: Example: NR2: This operation may be carried out from the PC using the ELDES Configuration Tool software. ATTENTION: NEVER add a phone number of the device’s SIM card as a user phone number! ATTENTION: Once User 1 phone number is set, it will be restricted to modify it only. 16 EN ESIM022 User manual v1.
7. DATE AND TIME The system comes equipped with internal real-time clock (RTC) that keeps track of the current date and time. Once the system is up and running, the user must set the correct date and time, otherwise the system will not operate properly. After shutting down and starting up the system, the date and time must be set again. Set date and time SMS Config Tool View date and time SMS Config Tool SMS text message content: CLK:yyyy.mm.dd_hr:mn Value: yyyy – year; mm – month, range – [01...
8. INPUTS The system comes equipped with 2 inputs identified as Z1 and Z2. Depending on the input and selected mode, the inputs are designed for different detection device connection, such as motion detectors, door contacts, temperature sensors etc. (see 8.1. Input Z1 and 8.2. Input Z2). Once the detection device is triggered, the system will send a notification to the user phone number (see 10. ALARM/RESTORE NOTIFICATIONS). 8.1. Input Z1 Input Z1 operates in Digital mode.
Set input as NO (normally open) SMS Config Tool View input state SMS SMS text message content: ZONE1:NO Example: ZONE1:NO This operation may be carried out from the PC using the ELDES Configuration Tool software. SMS text message content: STATUS Example: STATUS Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. View real-time input voltage Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software.
Set input mode as Temperature Sensor SMS Config Tool Set input mode as Digital View input mode parameters SMS SMS text message content: ZONE2:TEMP Example: ZONE2:TEMP This operation may be carried out from the PC using the ELDES Configuration Tool software. SMS text message content: ZONE2:DIG Example: ZONE2:DIG Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software.
Set threshold SMS Config Tool Set input as NC (normally closed) SMS Config Tool Set input as NO (normally open) SMS Config Tool View input state View real-time input voltage ESIM022 User manual v1.2 SMS SMS text message content: Z2VLEV:vthr Value: vthr – threshold, range - [0... 3000] mV Example: Z2VLEV:1390 This operation may be carried out from the PC using the ELDES Configuration Tool software.
View input parameters Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. For more details on how to manage the alarm/restore notifications, please refer to 10. ALARM/ RESTORE NOTIFICATIONS. For more details on how to view system’s information that may include input state, please refer to 13. SYSTEM INFORMATION. STATUS SMS. 8.2.
To view the temperature value of the temperature sensor, please refer to the following configuration methods. View temperature value and temperature sensor name SMS Config Tool SMS text message content: STATUS Example: STATUS This operation may be carried out from the PC using the ELDES Configuration Tool software. If a temperature sensor becomes faulty, it is recommended to remove it or replace it by a functional sensor.
Enable temperature sensor and set MIN and MAX temeprature thresholds and name View MIN and MAX thresholds View temperature sensor name and temperature value SMS SMS text message content: TEMPt1mnn:mxx:temp-name Value: mnn – MIN temperature threshold, range [-55... 125] C; mxx – MAX temperature threshold, range - [-55... 125] C; temp-name – up to 8 characters temperature sensor name.
ATTENTION: Colon, dash, comma characters are NOT allowed in temperature sensor name. NOTE: If the MIN or MAX temperature threshold is exceeded, the system will NOT send the Temperature Info SMS text message to the listed user phone number before the current temperature value has been updated. For more details on how to view system’s information that may include temperature sensor name and temperature value please refer to 13. SYSTEM INFORMATION. STATUS SMS.
10. ALARM/RESTORE NOTIFICATIONS The system can notify the listed user phone number by the following methods that can be used only individually: • SMS text message – in the event of input Z1, input Z2 or tamper alarm or restore. This method is selected by default. • Phone call – in the event of input Z1, input Z2 or tamper alarm only.
To manage input and/or tamper alarm and restore notifications by SMS text message, please refer to the following configuration methods. Disable input alarm notification SMS Config Tool Enable input alarm notification SMS Config Tool Set input alarm text SMS Config Tool Disable input restore notification SMS Config Tool ESIM022 User manual v1.2 SMS text message content: SAZi:OFF Value: i – input number, range – [1... 2].
Enable input restore notification SMS Config Tool Set input restore text SMS Config Tool Disable tamper alarm/restore notification SMS Config Tool Enable tamper alarm/restore notification SMS Config Tool 28 EN SMS text message content: SRZi:ON Value: i – input number, range – [1... 2] Example: SRZ1:ON This operation may be carried out from the PC using the ELDES Configuration Tool software. SMS text message content: TRZi:in-restore-text Value: i – input number, range – [1...
View alarm/ restore notification parameters Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. ATTENTION: Colon, dash, comma characters are NOT allowed in the input alarm/restore notification texts. For more details on how to set the tamper name that is included in the tamper alarm/restore notifications by SMS text message, please refer to 9. TAMPER.
To manage calls in the event of input or tamper alarm, please refer to the following configuration methods. Enable call in the event of input alarm SMS Config Tool Disable call in the event of input alarm SMS Config Tool Enable call in the event of tamper alarm SMS Config Tool Disable call in the event of tamper alarm SMS Config Tool 30 EN SMS text message content: CAZi:ON Value: i – input number, range – [1... 2].
View alarm notificaiton parameters Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. ATTENTION: Input alarm/restore notifications do NOT apply when input Z2 is set up to operate in Temperature Sensor mode. For more details, please refer to 8.2.2. Temperature Sensor Mode. ESIM022 User manual v1.
11. OUTPUT The system comes equipped with 1 open collector output C1 designed for electricalal appliance connection. Normally, the output can be used to arm/disarm a non-GSM alarm panel that has a zone configured as key-switch. The ouptut can also be used to open/close garage doors, activate lights, heating, watering and much more. When output turns ON, the system triggers any device or relay connected to it.
11.2. Turning Output ON and OFF By default, the output is turned OFF. To instantly turn ON/OFF the output, please refer to the following configuration methods. Turn ON output SMS Config Tool Turn OFF output SMS Config Tool View output status SMS Config Tool SMS text message content: OUT:ON Example: OUT:ON This operation may be carried out from the PC using the ELDES Configuration Tool software.
12. BACK-UP BATTERY AND MAINS POWER SUPPLY STATUS MONITORING The system may come equipped with a back-up battery maintaining the power supply of the system for up to 12 hours when the mains power supply is temporally lost. The implemented feature allows to perform a self-test on the backup battery every 6 seconds and notify the user by SMS text message under the following conditions: • Battery connected – battery is present. • Battery disconnected – battery is dead or missing.
Enable Battery Disconnected notification SMS SMS text message content: BATDIS:ON Example: BATDIS:ON Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. Set Battery Disconnected notification text Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software.
Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. If the household electricity is unstable in the system installation area, the system may temporally lose its power supply and continue operating on the back-up battery power. The system supervises the mains power supply every 6 seconds and notifiies the user by SMS text message when the mains power is lost or restored.
Set Mains Power Supply Restore notification text Disable Mains Power Supply Restore notification Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. SMS Config Tool View Backup Battery and Mains Power Supply notification parameters ESIM022 User manual v1.
13. SYSTEM INFORMATION. STATUS SMS The system supports an informational SMS text message identified as the Status SMS, which can be delivered upon request. Once requested, the system will reply with Status SMS that may provide the following: • System name. • System date & time. • GSM signal strength. • System’s internal temperature • Name and status (ON/OFF) of the output. • Input Z1 state / value. • Input Z2 state / value.
13.1. Periodic Status SMS Once enabled, the system sends Status SMS to listed user phone number periodically every 1 hour. Typically, this feature is used to verify the online status of the system. By default, periodic Status SMS is disabled. To enable/disable periodic Status SMS and/or set a different frequency, please refer to the following configuration methods.
14. SYSTEM NOTIFICATIONS When an event occurs, the system will follow this pattern: SMS a) The system attempts to send an SMS text message to the first listed user phone number only. b) If the user phone number is unavailable and the system fails to receive the SMS delivery report within 20 seconds, it will attempt to send the SMS text message to the next listed user phone number. The user phone number may be unavailable due to the following reasons: c) • mobile phone has been switched off.
Seq. No. Event Description 8 Mains Power Restore SMS text message sent to the user in case the mains power supply is restored. For more details on how to manage this notification, please refer to 12. BACK-UP BATTERY AND MAINS POWER SUPPLY STATUS MONITORING. 9 Battery Connected SMS text message sent to the user in case the battery level reaches the back-up battery is connected. For more details on how to manage this notification, please refer to 12.
By default, Device Started notification is disabled. To enable/disable it and set the text for this notification, please refer to the following configuration methods. Enable Device Started notification and set the text SMS Config Tool Disable Device Started notification SMS Config Tool SMS text message content: SSMS:start-text Value: start-text – up to 23 characters System Started notification text.
View system notification parameters Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. ATTENTION: Colon, dash, comma characters are NOT allowed in Device Started and Device Shutdown notification text. For more details on how the system notifies the user in the event of input or tamper alarm/restore, please refer to 10. ALARM/RESTORE NOTIFICATIONS.
15. ON-BOARD TEMPERATURE SENSOR The system features an on-board temperature sensor (by default – enabled) allowing to be notified when the device temperature exceeds the set up minimum (MIN) (by default is set to -10 °C) or maximum (MAX) (by default is set to 25 °C) temperature threshold values. If one of the thresholds is exceeded, the system will automatically deliver an SMS text message identified as the Internal Temperature SMS, to the listed user phone number.
Disable Answer Call feature SMS Config Tool Enable Answer Call feature SMS Config Tool Set microphone gain SMS Config Tool View remote listening parameters ESIM022 User manual v1.2 Config Tool SMS text message content: ANSWER:OFF Example: ANSWER:OFF This operation may be carried out from the PC using the ELDES Configuration Tool software. SMS text message content: ANSWER:ON Example: ANSWER:ON This operation may be carried out from the PC using the ELDES Configuration Tool software.
17. TECHNICAL SUPPORT 17.1.
17.3. Updating the Firmware via USB Cable 1. Disconnect the power supply, and back-up battery (if any). 2. Short circuit (connect) FW pins. 3. Connect the device via USB cable to the PC. 4. The new window must pop-up where you will find the .bin file. Otherwise open My Computer and look for CRP DISABLED drive. 5. Delete the .bin file found in the drive. 6. Copy the new firmware .bin file to the very same window. 7. Unplug USB cable. 8. Remove short circuit from FW pins. 9. Firmware updated.
18. RELATED PRODUCTS DC power supply Microphone 48 EN DS18S20 - temperature sensor Vinson DS18B20 - digital thermometer with 3m wire ESIM022 User manual v1.
ESIM022 User manual v1.
Made in the European Union www.eldes.