ESIM110 ESIM120 GSM SWITCH-GATE CONTROLLER
User Manual v3.1 Valid for ESIM110/ESIM120 v11.03.03 and up SAFETY INSTRUCTIONS Please read and follow these safety guidelines to safeguard yourself and others: • GSM switch-gate controller ESIM110/ESIM120 (later referred to as “the system” or “ the device”) contains a built-in radio transceiver operating in GSM 850/900/1800/1900 MHz bands. • DO NOT use the system where it can cause potential danger and interfere with other devices – such as medical devices.
CONTENTS 1. GENERAL INFORMATION............................................................................................................................................................6 2. TECHNICAL SPECIFICATIONS.....................................................................................................................................................6 2.1. Electrical & Mechanical Characteristics.....................................................................................................
EN ESIM110/ESIM120 Manual v.3.
Limited Liability The buyer agrees that the system will reduce the risk of fire, theft, burglary or other danger but that it does not guarantee against the occurrence of such events. “ELDES UAB” will not take any responsibility for the loss of personal effects, property or revenue whilst using the system. The liability of “ELDES UAB” is limited to the value of the system purchased.
1. GENERAL INFORMATION ESIM110/ESIM120 is a micro-controller based device intended to provide access control for gate automatics, road barriers or to remotely turn ON/OFF any electrical appliance via the GSM network. Examples of using the system: • Access control. • Parking lot control of residential houses or offices. • Gate control of private houses. • Any electrical appliance control: lighting, watering, heating etc. • Remote reboot of the “frozen” systems, such as computer network or a server.
2.2.
LED Indicator Functionality SIM STAT indication SIM card status OFF SIM card is not yet connected to the GSM network / SIM card is not present / PIN code enabled Steady ON SIM card is operating successfully NETW indication GSM signal strength OFF No GSM signal Flashing every 1 sec. Poor Flashing several times per sec. Medium Steady ON Excellent 2.3.
3. INSTALLATION • The system should be installed indoors, in stationary environment ONLY. • For the connection of input/output terminals, use 0.50 mm2 1 thread unshielded cable of up to 100 meters length. 1. Wire up the system in accordance with the wiring diagrams (see 2.3 Wiring Diagrams for more details). 2. Connect the GSM antenna.
4. GENERAL OPERATION When a phone call is made to the phone number of the SIM card inserted in ESIM110/ESIM120, the system will verify if the caller’s phone number exists in the memory. If the caller is one of the 5 administrators or the phone number belongs to one of the 500 database users, the system will reject the phone call, thus making the phone call free of charge, and open the gate. By ringing to ESIM110/ESIM120 again, it will close the gate.
The system supports the following remote connection modes: • CLIENT – The device connects to the configuration server making the device accessible through a web browser when the administrator logs in via ELDES website (see 5.3.1. Establishing Remote Connection). This mode is set by default and DOES NOT require the static IP address for the device SIM card. Default Client mode parameters are as follows: • Server IP – config.eldes.lt • DNS1 – 84.32.3.34 • DNS1 – 84.32.134.
Set remote connection mode as Client SMS Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER Set server IP address SMS This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser.
View remote configuration parameters SMS SMS text message content: ssss_SETGPRS? Value: ssss – 4-digit SMS password. Example: 1111_SETGPRS? Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER 5.3.1.Establishing Remote Connection 1. In order to activate a remote connection, please send the following SMS text message from user phone number.
NOTE: 0 value sets unlimited session duration. NOTE: ELDES Configuration Tool software and remote configuration web interface allows to set the unlimited session duration value. NOTE: Once the remote connection establishment by phone call is enabled, the specified administrator will no longer be able to control the output via free of charge phone call. 2. a) If running in Client mode, open a web browser and type in http://www.eldes.lt/login.
7. SMS PASSWORD For security reasons, the system uses the following type of password: • SMS password – 4-digit password used for system configuration and control from administrator phone number by SMS text messages and logging in to ELDES Configuration Tool software . By default, SMS password is 0000, which MUST be changed! Set SMS password SMS SMS text message content: wwww_PSW_ssss Value: wwww – 4-digit default SMS password; ssss – 4-digit new SMS password; range – [0001... 9999].
Assign output (-s) to individual administrator ONLY FOR ESIM120 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER Delete administrator phone number SMS SMS text message content: ssss_NRas:DEL Value: ssss – 4-digit SMS password; as – administrator phone number slot, range – [2... 5].
9. DATE AND TIME The system comes equipped with internal real-time clock (RTC) that keeps track of the current date and time. Once the system is up and running, the user must set the correct date and time, otherwise the system will not operate properly. By default, after shutting down and starting up the system, the date and time must be set again. In order to avoid manual date and time set up, please use the automatic date and time synchronization feature (see 9.1. Automatic Date and Time Synchronization).
By default, the date and time synchronization period is 30 days. To set a different period, please refer to the following configuration methods. Set synchronization period Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER NOTE: When setting up automatic date and time synchronization feature remotely, you may wish to restart the system when done.
10. USER PHONE NUMBER DATABASE The system comes equipped with a user database of 500 user capacity. When the phone number is set, the user will be able to control the output (-s) by free of charge phone call. ESIM120 user database allows to assign output C1, output C2 or both outputs (simultaneous control) to a certain user.
Assign output (-s) to individual user SMS ONLY FOR ESIM120 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser.
Disable user database SMS SMS text message content: ssss_DBM_OFF Value: ssss – 4-digit SMS password. Example: 1111_DBM_OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER To enable user database, please refer to the following configuration methods. Enable user database SMS SMS text message content: ssss_DBM_ON Value: ssss – 4-digit SMS password.
Remove scheduler from individual user SMS SMS text message content: ssss_NSCHED_ttteeellnnuumm_c:OFF or ssss_NSCHED_user-name_c:OFF Value: ssss – 4-digit SMS password; ttteeellnnuumm – up to 15 digits user phone number; c – scheduler number; range – [1... 8]; user-name – up to 16 characters user name. Example: 1111_NSCHED_John_5:OFF Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software.
Remove deadline from individual user SMS Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER Set ring counter for individual user SMS text message content: ssss_EXPIRYTIME_ttteeellnnuumm_0 or ssss_EXPIRYTIME_user-name_0 Value: ssss – 4-digit SMS password; ttteeellnnuumm – up to 15 digits user phone number; user-name – up to 16 characters user name.
NOTE: Multiple schedulers can be assigned/removed by a single SMS text message, Example: 1111_NSCHED_ John_2:ON_6:OFF_3:OFF_5:ON NOTE: 0 value removes the set up deadline from the user. NOTE: 0 value removes the set up ring counter from the user. 11. OUTPUT (-S) ESIM110 comes equipped with 1 built-in output, while ESIM120 – with 2 outputs.
View output name SMS SMS text message content: ssss_STATUS Value: ssss – 4-digit SMS password. Example: 1111_STATUS Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER ATTENTION: Space, colon, semi-colon characters, parameter names and/or values, such as PSW, STATUS, ON, OFF etc. are NOT allowed in output names. 11.2.
11.3. Output Control by SMS Text Message To open or close the gate, send the SMS text message from any of 5 available administrator phone numbers (see 8. USER PHONE NUMBER DATABASE for phone number management). The system will turn ON the output (-s) for a determined time period (pulse) resulting in the gate opening or closing, depending on the current gate state. The confirmation reply by SMS text message, containing the output name (see 11.1.
Turn OFF output/Set output start-up state as OFF SMS Example: 1111_C1:OFF ONLY FOR ESIM110 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER Turn ON output for time period SMS ONLY FOR ESIM120 SMS text message content: ssss_Co:ON:hr.mn.sc or ssss_out-name:ON:hr.mn.sc Value: ssss – 4-digit SMS password; o – output number, range - [1...
Turn ON output/Set output start-up state as ON SMS Example: 1111_C1:ON ONLY FOR ESIM120 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER Turn OFF output/Set output start-up state as OFF SMS text message content: ssss_Co:ON or ssss_out-name:ON Value: ssss – 4-digit SMS password; o – output number, range - [1... 2]; out-name – up to 16 characters output name.
11.4. Output Control Confirmation by Call Back The system can make a phone call confirming that the output control action has been successfully carried out. Once enabled, every output control action will be followed by a 5-second (by default) ring to the user/administrator phone number that the output control by free of charge phone call was initiated from. By default, output control confirmation by call back is disabled. To enable/disable it, please refer to the following configuration methods.
11.5. Output Control from any Phone Number By default, the system ignores any incoming calls from a non-preset phone number. To permit/deny output control by free of charge phone call (see 11. OUTPUT (-S)) from a non-preset phone number, please refer to the following configuration methods. Enable output control from any phone number SMS SMS text message content: ssss_STR:ON Value: ssss – 4-digit SMS password.
Remove scheduler SMS Example: 1111_OSCHED1_3:OFF ONLY FOR ESIM110 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER Assign scheduler SMS SMS text message content: ssss_OSHEDo_c:ON Value: ssss – 4-digit SMS password; o – output number, range [1 – output C1; 2 – output C2]; c – scheduler number; range – [1... 8].
12. SCHEDULERS The system comes equipped with 8 schedulers that allow to set up the day (-s) of the week and time parameters. The schedulers are used to set up user access restriction (see 10.1. User Validity and Access Restriction) as well as automatic output control (see 11.6. Automatic Output Control). Each scheduler includes the following parameters: • Every Day – Determines whether the scheduler will be valid everyday regardless of the current day of the week.
Set start time SMS SMS text message content: ssss_SCHEDc_st:hr:mn Value: ssss – 4-digit SMS password; c – scheduler number; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59]. Example: 1111_SCHED2_ST:20:25 Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser.
13. EVENT LOG This feature allows to chronologically register up to 1000 timestamped records regarding the following system events: • Output control including the user/administrator phone number and user name. • User validity expiry by deadline. • User validity expiry by ring counter. • Automatic output control beginning. • Automatic output control ending. To export the event log to .log file or clear it, please refer to the following configuration methods.
The event log may be set as of LIFO (last in, first out) type that allows the system to automatically replace the oldest records with the the latest ones. By default, LIFO type event log is disabled. To enable/disable it, please refer to the following configuration methods. Enable LIFO type log Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser.
14. INPUTS The system comes equipped with 3 inputs designed for fault indication output or detection device connection, such as door contacts. Once a fault indication output and/or a detection device is triggered, the system will send a notification to the administrator phone number. Typically, the inputs are used to receive notifications regarding jammed gate or gate state. For more details, please refer to 14.1. Input Names and Alarm Notifications.
View input names SMS SMS text message content: ssss_STATUS Value: ssss – 4-digit SMS password. Example: 1111_STATUS Config Tool This operation may be carried out from the PC using the ELDES Configuration Tool software. WEB This operation may be remotely carried out from the PC using the web browser. BROWSER By default, the system sends SMS text message to the first available administrator in case of input alarm.
14.2. Disabling and Enabling Inputs By default, all inputs are enabled. Once disabled, input alarm event will no longer be followed by an SMS text message. To disable/enable an individual input, please refer to the following configuration methods. Disable input SMS SMS text message content: ssss_Zn:OFF Value: ssss – 4-digit SMS password; n – input number, range – [1... 3]; input-name – up to 8 characters input name.
15. SYSTEM INFORMATION. INFO SMS The system supports an informational SMS text message identified as the Info SMS, which can be delivered upon request. Once requested, the system will reply with Info SMS that provides the following: • System date & time. • GSM signal strength. • Number of occupied and empty slots in the user database. • State of inputs (OK/alarm). Request for system information SMS SMS text message content: ssss_INFO Value: ssss – 4-digit SMS password.
16. SYSTEM NOTIFICATIONS In case of a certain event, the system attempts to send an SMS text message to the first preset administrator phone number only. If the administrator phone number is unavailable and the system fails to receive the SMS delivery report within 20 seconds, it will attempt to send the SMS text message to the next preset administrator phone number. The administrator phone number may be unavailable due to the following reasons: • mobile phone was switched off.
17. GPRS NETWORK SETTINGS The GPRS network settings are used for device communication with the remote configuration server or Smart Gate server via GPRS connection. To set the GPRS network settings, please refer to the following configuration methods. Set APN SMS SMS text message content: ssss_SETGPRS:APN:acc-point-name Value: ssss – 4-digit SMS password; acc-point-name – up to 31 character APN (Access Point Name) provided by the GSM operator.
18. REMOTE SYSTEM RESTART In some critical situations, a system restart may be required. To remotely carry out system restart, please refer to the following configuration method. Restart the system SMS SMS text message content: ssss_RESTART Value: ssss – 4-digit SMS password. Example: 1111_RESTART 42 EN ESIM110/ESIM120 Manual v.3.
19. TECHNICAL SUPPORT 19.1.
20. RELATED PRODUCTS ME1 – metal cabinet Power supply Adhesive flat GSM antenna 44 EN EBU1 – power backup unit IP66 - plastic enclosure Magnet mount straight GSM antenna ESIM110/ESIM120 Manual v.3.
Copyright © “ELDES UAB”, 2013. All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a warning. Hereby, “ELDES UAB” declares that wireless smoke detector EWF1 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Made in the European Union www.eldes.