Water quality
As a water heater is constantly flushed with fresh water, there are restrictions to the
maximum flow temperature related to the hardness of the water. The following table indicates
the maximum flow temperatures for different water hardness values. Not respecting these
values can lead to damage of the heat exchanger.
Maximum flow temperature related to water hardness
Water hardness Max. setpoint (P1) Temp. limiter setting High limit setting
[ºdH] [ºf] [ºC] [ºC] [ºC]
0 - 5 0 - 9 90 97 100
5 - 15 9 - 27 85 92 95
15 - 20 27 - 36 80 87 90
20 - 28 36 - 50 60 67 70
Hot water production
The following table shows the sanitary hot water tapping volumes which can be achieved
with a THISION-L/R40 water heater, based on a cold water inlet temperature of 10ºC.
Hot water tapping volumes (cold water = 10ºC)
Output
flow @50ºC
flow @60ºC flow @65ºC flow @70ºC flow @80ºC flow @90ºC
[kW] [l/min] [l/min] [l/min] [l/min] [l/min] [l/min]
TH-L/R40
50
45.7 16.3 13.1 11.9 10.9 9.3 8.2
TH-L/R40
65
60.8 21.8 17.5 15.9 14.6 12.5 10.9
TH-L/R40
85
81.1 29.1 23.3 21.2 19.4 16.6 14.6
TH-L/R40
100
92.9 33.4 26.7 24.3 22.2 19.1 16.7
TH-L/R40
120
111.6
40.1 32.1 29.1 26.7 22.9 20.0
TH-L-145/
R40-150
132.2
47.5 38.0 34.5 31.6 27.1 23.7